ブログ

ホーム / ブログ

射出成形

Clamp Force: You Cannot Size a Tonnage From a Table

Cavity pressure demand runs from 25 to 57 MPa as the flow ratio goes from 50 to 250, and the tonnage follows. Flash width falls from 0.35 to 0.01 mm between 20 and 60 MPa of held pressure, which is why adding tonnage to fix flash usually makes a different problem.

続きを読む "
Silicone Rubber Products

Release Agent: You Cannot Buy Easy Demoulding and a Bond

Six tenths of a phr of internal release cuts demoulding force from 180 to 75 newtons. At 1.5 phr it cuts it to 30 and takes secondary bond strength to 30 percent of control. Most of the release is in the first third of the dose, and all of the damage is in the last third.

続きを読む "