The braid is the pressure vessel, not the rubber
A silicone hose without reinforcement is a tube. It carries pressure until the wall stress exceeds the tensile strength of the rubber, which for silicone at 100 C is not much. The braid is what makes it a hose, because the fibres take the hoop and axial loads and the silicone only has to be a seal.
The fibres carry load in tension, and the tension depends on the angle at which they cross the axis. At one particular angle the geometry balances the hoop and axial loads so that the fibre is loaded purely in tension with no tendency to rotate or straighten. That angle is the arctangent of the square root of two, 54.7 degrees, and it is the same angle that appears in pressure vessels, in biological tissue and in the Clapeyron net.
Measured burst pressure against braid angle: 12 bar at 30 degrees, 17 at 40, 21 at 50, 22 at 55, 17 at 65 and 11 at 80. The curve is symmetric around the optimum in theory and slightly skewed in practice, because the braid also has to be manufacturable at the ends.
What going off the optimum actually does
A braid at 30 degrees is too close to the axis. Under pressure the hose tries to lengthen and the braid angle increases towards the optimum, so the hose grows in length and shrinks in diameter before it fails. That movement is visible as a hose that gets longer when it is pressurised, and it is a common complaint on low-angle braids.
A braid at 80 degrees is too close to the hoop. Under pressure the hose tries to shorten and swell, the angle decreases towards the optimum, and the hose grows in diameter. It fails by bursting along the fibre direction rather than across it, which produces a long split rather than a hole.
Both failures are progressive rather than instant. The hose moves towards the optimum angle as it is pressurised, so a braid that is off-angle does not fail at the rated pressure on the first cycle. It creeps towards the optimum over hundreds of cycles and fails later, which makes the defect look like a material fatigue problem.
Carriers set the strength, angle sets the efficiency
Once the angle is right, burst pressure scales with the amount of fibre. Measured against carrier count: 14 bar at 24 carriers, 20 at 36, 26 at 48 and 31 at 64. The relationship is close to linear because each carrier adds the same amount of fibre at the same angle.
That gives a designer two independent knobs, which is the useful part. Carrier count sets the strength at a fixed diameter, and angle sets how efficiently the fibre is used. A hose that needs 30 bar can be built with 64 carriers at the optimum angle, or with more carriers at a worse angle, and the first option is lighter and cheaper.

| Braid angle | Burst pressure | What the hose does under pressure |
|---|---|---|
| 30 degrees | 12 bar | Lengthens, narrows, creeps towards optimum |
| 40 degrees | 17 bar | Lengthens slightly, stable |
| 50 degrees | 21 bar | Nearly stable, the practical target |
| 55 degrees | 22 bar | Balanced, no length or diameter change |
| 65 degrees | 17 bar | Shortens, swells, moves off optimum |
| 80 degrees | 11 bar | Swells strongly, splits along the fibre |
Table 1 — Braid angle against burst pressure, and the movement that gives it away
The mandrel decides the bore, and the bore decides the braid
A silicone hose is built on a mandrel, and the mandrel is what keeps the bore open while the rubber is applied, the braid is laid over it and the whole assembly is vulcanised. The mandrel diameter sets the finished bore, and the braid is laid over a diameter that is larger than the finished bore because the rubber underneath has thickness.
That means the braid angle is set on a diameter that the customer never sees, and the angle that results on the finished hose is slightly different from the angle the machine was set to. A hose with a thick inner liner and a thin cover has its braid at a larger diameter relative to the bore than a thin-lined hose, and its effective angle is different.
The mandrel also sets the length. Silicone shrinks during vulcanisation, and the shrinkage is restrained by the mandrel in the bore but not in the length. A hose pulled off a straight mandrel comes out slightly shorter than it went on, and a hose made on a curved mandrel has to account for the curve in its cut length.
| العيب | السبب | Fix |
|---|---|---|
| Hose lengthens under pressure | Braid angle below optimum | Increase the angle towards 54.7 degrees |
| Hose swells and splits lengthwise | Braid angle above optimum | Decrease the angle, check the braid tension |
| Burst below rating with correct angle | Carrier count or fibre specification | More carriers, or a higher tenacity yarn |
| Bore collapses on the bend | Wall too thin, or mandrel radius too tight | Thicker liner, larger bend radius |
| Braid shows through the cover | Cover too thin over the braid crown | Thicker cover, or a smaller braid diameter |
Table 2 — Hose failures read back to the braid or the mandrel
How to test a hose you did not design
Burst testing is destructive and slow, so most hose is qualified by a sample and then trusted. The trust is misplaced if the braid angle drifts, and it drifts whenever the braider tension changes, which happens with wear on the carriers and with a change of yarn lot.
Two measurements catch most of it without a burst test. The first is the change in length under pressure: a hose at the optimum angle does not change length, and a hose that grows by 2 percent at rated pressure is a hose whose angle is wrong. The second is the braid angle itself, measured on a cut section with a protractor, which takes a minute and is almost never done.
A pressure-hold test at 1.5 times the rated pressure for one minute catches the gross failures. It does not catch the off-angle braid, because an off-angle hose holds pressure perfectly well until it has crept. That is why the length measurement matters more than the pressure test for this particular defect.
What to specify
A hose specification that can be enforced names the braid, not only the performance.
- Burst pressure and the test temperature, since silicone loses strength quickly above 120 C.
- Braid angle, with a tolerance of a few degrees, measured on a cut section.
- Carrier count and yarn specification, because burst pressure follows both.
- The change in length at rated pressure, which is the cheapest check on the angle.
- Mandrel diameter and the finished bore, since the two differ by the liner thickness.
Add the bend radius and the working temperature, because a hose that passes a straight burst test can still collapse on a tight bend at 130 C. The burst test measures the braid; the application measures the wall.
Why is 54.7 degrees the optimum braid angle?
It is the angle at which the fibre carries the hoop and axial loads in pure tension, with no tendency to rotate. It is the arctangent of the square root of two.
What happens if the braid angle is too low?
The hose lengthens and narrows under pressure and creeps towards the optimum angle, so it fails later rather than immediately.
Does carrier count matter as much as angle?
It matters, but it is a linear effect. Angle is an efficiency effect, and going from 80 to 55 degrees doubles burst pressure with the same fibre.
How can I check the braid angle without a burst test?
Measure the change in length at rated pressure. A hose at the optimum angle does not change length; 2 percent growth means the angle is wrong.
Why does the braid angle on the finished hose differ from the machine setting?
The braid is laid over the liner, at a larger diameter than the finished bore, so the effective angle on the finished hose is slightly different.
What causes a lengthwise split?
A braid angle above the optimum. The hose swells and fails along the fibre direction rather than across it.
A hose that has to hold pressure hot?
Send the bore, the working pressure, the temperature and the bend radius. We will work out the braid angle and carrier count, and what the hose will do at temperature.
Continue reading
- Silicone Compression Moulding: Cycle, Flash and Consistency
- Silicone Extrusion: Curing, Tolerance and the Profile That Holds
- Cold Runner Silicone: You Buy the Material Back With Temperature
- Silicone Vulcanization Temperature: Twenty Degrees Halves the Cure
- Custom Silicone Rubber: Moulding, Tooling and Tolerances