The problem
Symptom. A bore is measured with a gauge whose resolution is wider than one tenth of the tolerance, so the same part flips between pass and fail on repeated reads.
What it costs. An indeterminate boundary decision forces an illustrative 11 h of repeated measurement and a stop-ship while the right gauge is sourced.
This article quantifies the repeatability gap against the ten-to-one rule, sets the resolution requirement, and writes the gauge selection into the control plan.
When gauge resolution breaks the boundary call
In one illustrative case a bore with a 0.10 mm tolerance is measured with a gauge reading to 0.02 mm, so the ratio is only 5 to 1 against the ten-to-one rule. The same part flips between pass and fail on repeated reads, and the verdict is no longer trustworthy.
| Rule trigger | What it causes | First figure to check |
|---|---|---|
| Resolution below 10:1 | Verdict flips on re-read | Ratio vs tolerance |
| Same part fails twice | Stop-ship while sourced | Illustrative 11 h rework |
| Boundary call unstable | Customer distrusts read | Gauge read step |
| Tolerance 0.10 mm | Gauge reads 0.02 mm | Required 0.01 mm |
Table 1 - Reading a resolution-rule failure before sourcing the gauge
Need a fixed price for this moulded part?
Send the 2D drawing, resin grade and annual volume. Our engineers return a DFM review, a material recommendation and a written quotation you can compare line by line.
Quantify the repeatability gap against 10 to 1
Quantify the gap before sourcing. Five resolution ratios return illustrative repeatability gaps of 18, 11, 7, 4 and 2 %; only the 10-to-1 ratio reaches the 2 % target. These are illustrative worked values from stated assumptions, not a measured series or a quoted result.
A five-step diagnostic sequence
- Read the tolerance.
Write the bore tolerance so the required resolution has a reference before any gauge is picked. - Compute the ratio.
Divide the tolerance by ten to get the maximum gauge step, here 0.01 mm for a 0.10 mm tolerance. - Pick the gauge.
Select a gauge reading at or below that step and reject any coarser option. - Verify the boundary.
Re-read a near-limit part twice to confirm the verdict does not flip. - File the gauge list.
Record the ratio so the next selection uses the same rule.
The chart below is a typical result from that measurement step. Use it to separate a design limit from a setting that can still be recovered.

Set the resolution requirement for the tolerance
Set the requirement at a 10-to-1 resolution ratio. With a 0.10 mm tolerance the gauge must read to 0.01 mm; an illustrative 11 h of repeated measurement is the cost of the wrong gauge. These are illustrative worked values from stated assumptions, not a market survey, a quoted price or a measured series.
| Clause or parameter | Agreed value | What goes wrong outside it |
|---|---|---|
| Resolution ratio | At least 10 to 1 | Verdict flips on re-read |
| Boundary verification | Two reads at edge | Unstable call shipped |
| Ratio on gauge list | Stated per feature | Wrong gauge reused |
| List owner | Named per programme | Rule applied loosely |
Table 2 - Resolution clauses for the control plan
A controlled gauge-selection sequence
Run the selection in a fixed order: read the tolerance, compute the required resolution, pick the gauge, then verify the boundary call. The table ranks the actions by verdict risk so the resolution rule is never skipped.
| Control action | What it fixes | Cost or trade-off |
|---|---|---|
| Set 10:1 ratio | Stable boundary call | Finer gauge cost |
| Verify boundary reads | No flip on re-read | Extra checks at edge |
| State ratio on list | No ambiguity | List longer to keep |
| Re-check on tolerance | No drift after change | One owner to maintain |
Table 3 - Resolution controls ranked by verdict risk
Write the resolution rule into the control plan
Put the rule in the control plan: gauge resolution at least one tenth of the tolerance, boundary calls verified, and the ratio stated on the gauge list. A written rule turns a flipping verdict into a stable read.
Not sure whether the fault is in the tool or the process?
Send us the drawing, the process window and a few sample parts. We will tell you which change fixes the fault before you commit to a tool modification.
What to send us
- Part drawing with the affected dimension
- Current process settings
- Sample parts from a good and a bad batch
- Annual volume
Keep the gauge list current between changes
Re-check the gauge list at each tolerance change, record the 11 h actually avoided, and re-forecast the resolution needs. A written list reviewed on dated evidence settles the resolution question at selection rather than at the boundary.
Before you release this injection moulding job
- The control plan sets gauge resolution at least one tenth of the tolerance
- A 0.10 mm tolerance uses a gauge reading to 0.01 mm or finer
- Boundary calls are verified with two reads at the edge
- The resolution ratio is stated on the gauge list per feature
- A named owner re-checks the list at each tolerance change
Attach this list to the RFQ. Most moulding faults are decided at the drawing stage.
Why ten to one?
A gauge step coarser than one tenth of the tolerance eats too much of the band, so the same part can read pass then fail. The ratio is a stated assumption for this illustrative case, not a measured survey.
How much does the wrong gauge cost?
Using illustrative assumptions the flipping verdict forces 11 h of repeated measurement and a stop-ship while the right gauge is sourced.
What resolution do I need?
Divide the tolerance by ten. For a 0.10 mm bore the gauge must read to 0.01 mm; anything coarser fails the rule.
Can I round the reading?
No, rounding to a coarse gauge step is exactly what creates the flip. The finer gauge removes the rounding ambiguity.
Who owns the gauge list?
A named programme owner re-checks it at tolerance changes. Without one owner the ratio is applied loosely.
Does the list expire?
It is valid until the tolerance changes. Re-checking at each change keeps the resolution evidence current.
Get a mouldable part and a fixed quotation
Send us the part file and the failure history. Our engineers will return a DFM review, a material recommendation and a fixed quotation with a defined first-article acceptance test.
To get an accurate quote, send:
- 3D file or 2D part drawing
- Resin grade and any regrind limit
- Annual volume and target unit price
- The failed sample or defect photos
Request a DFM review and quote
Prefer to talk it through first?
البريد الإلكتروني [email protected] or message us on WhatsApp +86 177 1752 9949. Send a drawing, a sample or a specification and an engineer will reply.
Why buyers work with Uplastech
ISO 9001, ISO 14001 and ISO 45001 certified. Founded in 2016, with injection moulding lines in Shanghai and an extrusion plant in Jiangsu. Moulding machines from 90T to 1100T and a maximum shot weight of 5100 g. Samples and a written quotation are available on request.