{"id":10263,"date":"2026-11-15T01:00:00","date_gmt":"2026-11-15T01:00:00","guid":{"rendered":"https:\/\/uplastech.com\/?p=10263"},"modified":"2026-11-15T07:07:35","modified_gmt":"2026-11-15T07:07:35","slug":"thick-enclosure-housing-cnc-trim-tolerance","status":"publish","type":"post","link":"https:\/\/uplastech.com\/ru\/thick-enclosure-housing-cnc-trim-tolerance\/","title":{"rendered":"CNC Trim Tolerance on Housings: Where the Cut Edge Misses the Datum"},"content":{"rendered":"<style>\n.upl-blog{font-size:17px;line-height:1.78;color:#1f2937}\n.upl-blog p{margin:0 0 18px}\n.upl-blog h2{font-size:26px;line-height:1.3;color:#0b2b33;margin:46px 0 14px;font-weight:700;letter-spacing:-.015em}\n.upl-blog h3{font-size:19.5px;color:#0d3b47;margin:28px 0 10px;font-weight:700}\n.upl-blog ul,.upl-blog ol{margin:0 0 20px;padding-left:22px}\n.upl-blog li{margin:0 0 9px}\n.upl-blog figure{margin:0 0 34px}\n.upl-blog figure img{width:100%;height:auto;display:block;border-radius:10px}\n.upl-blog figcaption{font-size:13px;color:#6b7280;margin-top:10px;line-height:1.5}\n.upl-blog .toc{background:none;border:0;border-radius:0;padding:0;margin:0 0 34px}\n.upl-blog .toc .lwptoc{margin:0}\n.upl-blog .toc h4{margin:0 0 10px;font-size:13px;letter-spacing:.1em;text-transform:uppercase;color:#0d5563}\n.upl-blog .toc ol{margin:0;padding-left:18px;font-size:14.5px}\n.upl-blog .toc li{margin-bottom:6px}\n.upl-blog table{width:100%;border-collapse:collapse;font-size:14.5px;margin:0 0 10px}\n.upl-blog th{background:#0d3b47;color:#fff;text-align:left;padding:11px 13px;font-weight:600;font-size:13.5px;border:0}\n.upl-blog td{padding:11px 13px;border:0;border-bottom:1px solid #e8ebed;vertical-align:top}\n.upl-blog tbody tr:nth-child(even){background:#fafbfc}\n.upl-blog .tablecap{font-size:12.5px;color:#6b7280;margin:0 0 30px}\n.upl-blog .myth{background:#fff8ef;border:1px solid #f6ddbd;border-radius:8px;padding:16px 20px;margin:0 0 26px;font-size:15.5px}\n.upl-blog .myth b{color:#a85c10}\n.upl-blog .callout{background:#f2f8f9;border-radius:8px;padding:18px 22px;margin:0 0 26px;font-size:15.5px;border-left:3px solid #14707f}\n.upl-blog .faq h3{border-top:1px solid #eceff1;padding-top:22px;margin-top:0;font-size:18px}\n.upl-blog .faq h3:first-of-type{border-top:0;padding-top:0}\n.upl-blog .cta{background:linear-gradient(135deg,#0b2b33,#0d5563);color:#fff;border-radius:12px;padding:34px;margin:48px 0 30px}\n.upl-blog .cta h2,.upl-blog .cta .cta-h{color:#fff;margin:0 0 10px;font-size:24px;font-weight:700;line-height:1.3}\n.upl-blog .cta p{color:#c9dee3;margin:0 0 20px;font-size:16px}\n.upl-blog .btn{display:inline-block;background:#e07a1f;color:#fff;text-decoration:none;font-weight:700;padding:13px 26px;border-radius:8px;font-size:15.5px}\n.upl-blog .rel{border-top:1px solid #e8ebed;margin-top:40px;padding-top:26px}\n.upl-blog .rel h4{font-size:13px;letter-spacing:.1em;text-transform:uppercase;color:#6b7280;margin:0 0 14px}\n.upl-blog .rel ul{list-style:none;padding:0;margin:0}\n.upl-blog .rel li{padding:11px 0;border-bottom:1px dashed #e8ebed}\n.upl-blog .rel a{text-decoration:none;font-weight:600;font-size:15.5px}\n\/* ==UPL-CONVERSION-MODULES-START== 2024 problem-solving \/ lead-gen blocks *\/\n.upl-blog .mod-h{font-size:12.5px;letter-spacing:.12em;text-transform:uppercase;font-weight:700;color:#0d5563;margin:0 0 12px}\n.upl-blog .problem{background:#fff8f3;border:1px solid #f3ddc9;border-left:4px solid #e07a1f;border-radius:10px;padding:22px 26px;margin:0 0 32px;font-size:16px}\n.upl-blog .problem p{margin:0 0 10px}\n.upl-blog .problem p:last-child{margin-bottom:0}\n.upl-blog .problem .mod-h{color:#a85c10}\n.upl-blog .problem .problem-promise{font-weight:700;color:#0b2b33}\n.upl-blog .steps{background:#f7fafb;border:1px solid #e1ebee;border-radius:10px;padding:22px 26px;margin:0 0 28px}\n.upl-blog .steps ol{list-style:none;counter-reset:uplst;margin:0;padding:0}\n.upl-blog .steps li{counter-increment:uplst;position:relative;padding:0 0 16px 42px;margin:0;font-size:15.5px}\n.upl-blog .steps li:last-child{padding-bottom:0}\n.upl-blog .steps li::before{content:counter(uplst);position:absolute;left:0;top:2px;width:26px;height:26px;border-radius:50%;background:#0d5563;color:#fff;font-size:13px;font-weight:700;line-height:26px;text-align:center}\n.upl-blog table.spec th{background:#14707f}\n.upl-blog .conv{background:#eef6f7;border:1px solid #cfe4e8;border-radius:10px;padding:24px 26px;margin:32px 0}\n.upl-blog .conv p{margin:0 0 12px;font-size:15.5px}\n.upl-blog .conv .conv-lbl{font-weight:700;color:#0b2b33;margin:16px 0 8px}\n.upl-blog ul.conv-need{list-style:none;padding:0;margin:0 0 20px;display:grid;grid-template-columns:1fr 1fr;gap:6px 18px}\n.upl-blog ul.conv-need li{position:relative;padding-left:20px;margin:0;font-size:14.5px}\n.upl-blog ul.conv-need li::before{content:\"\";position:absolute;left:0;top:9px;width:9px;height:9px;border:2px solid #14707f;border-radius:2px}\n.upl-blog .conv-btn{display:inline-block;background:#0d5563;color:#fff;text-decoration:none;font-weight:700;padding:11px 22px;border-radius:7px;font-size:15px}\n.upl-blog .checklist{background:#fbfcfd;border:1px solid #e3e9ec;border-radius:10px;padding:24px 26px;margin:36px 0}\n.upl-blog .checklist ul{list-style:none;padding:0;margin:0 0 12px}\n.upl-blog .checklist li{position:relative;padding-left:28px;margin:0 0 10px;font-size:15.5px}\n.upl-blog .checklist li::before{content:\"\";position:absolute;left:0;top:7px;width:14px;height:14px;border:2px solid #0d5563;border-radius:3px}\n.upl-blog .cl-note{font-size:13.5px;color:#6b7280;margin:0}\n.upl-blog .cta .cta-lbl{color:#c9dee3;font-weight:700;margin:0 0 8px;font-size:14.5px}\n.upl-blog ul.cta-need{list-style:none;padding:0;margin:0 0 22px;display:grid;grid-template-columns:1fr 1fr;gap:4px 18px}\n.upl-blog ul.cta-need li{color:#e4f0f2;font-size:14.5px;padding-left:18px;position:relative;margin:0}\n.upl-blog ul.cta-need li::before{content:\"\\2713\";position:absolute;left:0;color:#e07a1f;font-weight:700}\n\/* ==UPL-CONVERSION-MODULES-END== *\/\n@media(max-width:640px){.upl-blog h2{font-size:22px}.upl-blog table{font-size:13px}.upl-blog .cta{padding:24px}.upl-blog ul.conv-need,.upl-blog ul.cta-need{grid-template-columns:1fr}.upl-blog .problem,.upl-blog .steps,.upl-blog .conv,.upl-blog .checklist{padding:18px}}\n\/* Single-post: hide the greeting card, keep the round WhatsApp bubble.\n   The Click to Chat logic refuses to open a chat while the greeting node exists,\n   so Code Snippets #9 removes that node from the DOM. This rule is only the visual fallback.\n   Delete #9 before removing this rule. *\/\nbody.single-post .ht_ctc_chat_greetings_box{display:none !important}\n<\/style>\n<div class=\"upl-blog\">\n<figure><img decoding=\"async\" src=\"https:\/\/uplastech.com\/wp-content\/uploads\/2026\/11\/thk-cover-trim.jpg\" alt=\"CNC Trim Tolerance on Housings: Where the Cut Edge Misses the Datum\" \/><figcaption>Thick-gauge forming: a production part is the only useful reference for a discussion about process drift.<\/figcaption><\/figure>\n<p class=\"lead\">A formed housing can be dimensionally sound yet fail assembly when the CNC trim is referenced to the wrong datum; define the locating scheme up front.<\/p>\n<div class=\"toc\"><\/div>\n<h2 id=\"what\">What the failure looks like on the line<\/h2>\n<p>A thick-gauge enclosure is bought as a finished visible surface, so forming and trimming faults become commercial faults the moment the cover is fitted.<\/p>\n<p>Trimmed housings show cut edges that sit off the mounting line, and the error grows on parts that were still warm or poorly located in the trim fixture.<\/p>\n<p>Vacuum-formed parts have no rigid, moulded datum in the way an injection-moulded part does, so the trim fixture must create the reference from formed surfaces that themselves vary. Any movement of the part in the fixture, or any post-forming relaxation after the cut, appears directly as edge-position error.<\/p>\n<p>Buyers and suppliers usually agree on the drawing and disagree on the conditions under which the drawing was checked. On a buyer's specification this distinction matters: a part can measure inside tolerance and still fail in use, because the drawing records geometry while the complaint records behaviour. Trim feed rate is usually the first value both sides compare, and it is also the one most often quoted without the conditions attached to it.<\/p>\n<h2 id=\"window\">The process window that decides it<\/h2>\n<p>Four variables move this result more than the rest. The ranges below are illustrative engineering guidance for a first discussion; confirm them on your own tool, material grade and part geometry before they become contract terms.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u041f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f<\/th>\n<th>Typical window<\/th>\n<th>What fails outside it<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Trim feed rate<\/td>\n<td>1-3 m\/min for 3-6 mm sheet<\/td>\n<td>Faster feeds push the part and open the edge tolerance<\/td>\n<\/tr>\n<tr>\n<td>Part temperature at trim<\/td>\n<td>Within 5 C of ambient<\/td>\n<td>Warm parts keep relaxing after the cut<\/td>\n<\/tr>\n<tr>\n<td>Fixture locating points<\/td>\n<td>6 points in a 3-2-1 scheme<\/td>\n<td>Over- or under-location lets the part shift between cycles<\/td>\n<\/tr>\n<tr>\n<td>Cutter runout<\/td>\n<td>Below 0.05 mm TIR<\/td>\n<td>Excess runout widens the cut and frays the edge<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"tablecap\">Table 1. Starting window for a joint process trial. Values are engineering guidance, not a measured survey.<\/p>\n<p><b>Trim feed rate<\/b> is typically held at 1-3 m\/min for 3-6 mm sheet. Faster feeds push the part and open the edge tolerance Record it together with the measurement point and the moment in the cycle; a single number without a location is not a process setting.<\/p>\n<p><b>Part temperature at trim<\/b> is typically held at Within 5 C of ambient. Warm parts keep relaxing after the cut When this drifts, the symptom usually appears at one cavity, one sheet position or one lane before it appears across the whole batch.<\/p>\n<p><b>Fixture locating points<\/b> is typically held at 6 points in a 3-2-1 scheme. Over- or under-location lets the part shift between cycles A change here is cheap during a trial and expensive after tooling release, so treat it as a controlled variable with a documented re-approval.<\/p>\n<p><b>Cutter runout<\/b> is typically held at Below 0.05 mm TIR. Excess runout widens the cut and frays the edge Put it on the change-control list, otherwise an unannounced material or setting substitution will be mistaken for ordinary process noise.<\/p>\n<h2 id=\"response\">Reading the response curve<\/h2>\n<figure><img decoding=\"async\" src=\"https:\/\/uplastech.com\/wp-content\/uploads\/2026\/11\/thick-enclosure-housing-cnc-trim-tolerance-chart.jpg\" alt=\"CNC Trim Tolerance on Housings: Where the Cut Edge Misses the Datum: Parts within trim tolerance (%) against Trim feed rate (m\/min)\" \/><figcaption>Figure 1. Left: Parts within trim tolerance (%) against Trim feed rate (m\/min). Right: how audited failures of this type typically split by cause. All plotted values are illustrative engineering guidance, not a measured survey.<\/figcaption><\/figure>\n<p>The left panel shows parts within trim tolerance (%) as trim feed rate (m\/min) increases: the response falls from 96 to 15 on the illustrative 0&ndash;100 scale. The dashed line at 70 marks a proposed acceptance limit, not a universal standard. Move that line only after the test method and the sample plan have been agreed, otherwise two suppliers can both be compliant and still deliver different parts.<\/p>\n<p>Read the shape rather than a single point. A curve that changes quickly near the limit is more sensitive to ordinary process noise than one that approaches it gradually, and that difference should be reflected in how tightly the setting is controlled and how often it is checked.<\/p>\n<h2 id=\"causes\">Where the causes actually sit<\/h2>\n<p>The right panel of Figure 1 splits audited failures of this type into five groups. The percentages are illustrative engineering guidance for prioritising an investigation, not a measured survey and not a prediction for your line.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u041f\u0440\u0438\u0447\u0438\u043d\u0430<\/th>\n<th>Illustrative share<\/th>\n<th>First check<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Datum scheme mismatch<\/td>\n<td>30%<\/td>\n<td>Confirm the datum scheme on the drawing matches the trim fixture&#x27;s locators.<\/td>\n<\/tr>\n<tr>\n<td>Part still warm at trim<\/td>\n<td>24%<\/td>\n<td>Measure the part temperature immediately before it is clamped for trimming.<\/td>\n<\/tr>\n<tr>\n<td>Fixture hold-down weak<\/td>\n<td>20%<\/td>\n<td>Check vacuum and clamp hold-down at every locating point.<\/td>\n<\/tr>\n<tr>\n<td>Feed rate too high<\/td>\n<td>16%<\/td>\n<td>Measure the first-off cut edge against the datum, not against the formed edge.<\/td>\n<\/tr>\n<tr>\n<td>Cutter runout or tool wear<\/td>\n<td>10%<\/td>\n<td>Re-measure a retained part after conditioning to detect post-trim movement.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"tablecap\">Table 2. Cause split and the corresponding first check. Shares are indicative and sum to 100.<\/p>\n<p><b>Datum scheme mismatch<\/b> accounts for roughly 30% of the illustrative split. Confirm the datum scheme on the drawing matches the trim fixture&#x27;s locators. Start here before authorising a material or tooling change, because it is the fastest explanation to confirm or eliminate.<\/p>\n<p><b>Part still warm at trim<\/b> accounts for roughly 24% of the illustrative split. Measure the part temperature immediately before it is clamped for trimming. Start here before authorising a material or tooling change, because it is the fastest explanation to confirm or eliminate.<\/p>\n<p><b>Fixture hold-down weak<\/b> accounts for roughly 20% of the illustrative split. Check vacuum and clamp hold-down at every locating point. Start here before authorising a material or tooling change, because it is the fastest explanation to confirm or eliminate.<\/p>\n<h2 id=\"checks\">Checks before sign-off<\/h2>\n<p>Run the same sequence on a retained good sample and on the disputed batch so the comparison means something.<\/p>\n<ol>\n<li>Confirm the datum scheme on the drawing matches the trim fixture&#x27;s locators.<\/li>\n<li>Measure the part temperature immediately before it is clamped for trimming.<\/li>\n<li>Check vacuum and clamp hold-down at every locating point.<\/li>\n<li>Measure the first-off cut edge against the datum, not against the formed edge.<\/li>\n<li>Re-measure a retained part after conditioning to detect post-trim movement.<\/li>\n<\/ol>\n<p>Keep a retained reference sample beside every result. When a batch is disputed, the comparison that settles it is almost always between the retained part and the current one under the same method, not between either part and a number on a drawing. Record the instrument, the operator, the conditioning time and the position on the part or sheet for each reading.<\/p>\n<h2 id=\"specification\">Writing it into the specification and the evidence pack<\/h2>\n<p>Cut-edge position shall be measured from the agreed datums after the part reaches ambient, with the trim fixture&#x27;s locating scheme and measurement temperature stated in the inspection plan.<\/p>\n<p>Write the requirement as a behaviour at a stated condition, not as a brand of material or a machine setting. State the test method, the conditioning, the sample plan and the rule for deciding a pass. Where a document is needed, ask the supplier for documentation that covers the actual construction and check its scope against your own market before approval; a document for the base material alone does not describe the finished part you are buying.<\/p>\n<p>At first-article approval, freeze the drawing revision, the material and colour identification, the process window, the tool and cavity identification, and the inspection method. Any later change to grade, site, tool, or window should trigger a new first article rather than a paper waiver. Keep retained samples from the approved lot and from each production lot so that a future comparison is possible.<\/p>\n<table>\n<thead>\n<tr>\n<th>Evidence item<\/th>\n<th>What it must show<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Approved drawing and revision<\/td>\n<td>The exact geometry and tolerances the decision applies to<\/td>\n<\/tr>\n<tr>\n<td>Material and colour identification<\/td>\n<td>Grade, supplier, colour reference and any declared recycled content<\/td>\n<\/tr>\n<tr>\n<td>Process window and change log<\/td>\n<td>The agreed settings and any deviation since approval<\/td>\n<\/tr>\n<tr>\n<td>Inspection record and retained samples<\/td>\n<td>Method, conditions, results and a physical reference from the same lot<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"tablecap\">Table 3. Minimum evidence pack for a first-article decision and a later batch dispute.<\/p>\n<p>None of the figures above should be read as a measured survey. They are engineering guidance for framing a joint trial; confirm them on your own tool, grade and geometry before they become contract terms.<\/p>\n<div class=\"faq\">\n<h2 id=\"questions\">Questions buyers ask<\/h2>\n<h3>Is this a material problem or a process problem?<\/h3>\n<p>Vacuum-formed parts have no rigid, moulded datum in the way an injection-moulded part does, so the trim fixture must create the reference from formed surfaces that themselves vary. Any movement of the part in the fixture, or any post-forming relaxation after the cut, appears directly as edge-position error. It is worth separating the two before a supplier changes a grade: hold the material constant for one controlled run, then move one setting at a time. If the symptom follows the setting, the material was never the cause.<\/p>\n<h3>Can trim feed rate be traded against cycle time?<\/h3>\n<p>Only within the window stated in Table 1, and only with a recorded trial. Faster feeds push the part and open the edge tolerance A faster cycle that sits outside the window usually moves the failure downstream, where it costs more to find.<\/p>\n<h3>What should be recorded at incoming inspection?<\/h3>\n<p>Keep the measurement, the method, the sample identity and the conditions together. Confirm the datum scheme on the drawing matches the trim fixture&#x27;s locators. A result without its conditions cannot be compared with a later batch.<\/p>\n<h3>Does a change of enclosure housing require re-approval?<\/h3>\n<p>Treat any change to material grade, tool, site or process window as a change that needs a new first-article decision. For thick-gauge forming work the drawing alone is not enough; the process route is part of what was approved.<\/p>\n<h3>How many samples are enough for a first-article decision?<\/h3>\n<p>There is no universal number. Sample across cavities, lanes, sheet positions or reel lengths so that the spread is visible, not just the average. Agree the sample plan and the acceptance rule with the supplier before the trial starts.<\/p>\n<h3>What belongs in the evidence pack?<\/h3>\n<p>The approved drawing and revision, the material and colour identification, the process window, the inspection method and results, the retained reference samples, and documentation covering the actual construction. Ask the supplier to state the scope of each document and check it against your own market.<\/p>\n<\/div>\n<div class=\"cta\">\n<p class=\"cta-h\">Seeing this on a current thick-gauge forming job?<\/p>\n<p>Send the drawing, the material and grade, the process window you are running, and the point in the cycle or the shelf life where the fault appears. We will help you separate a material question from a process question and a specification question before anyone changes a tool.<\/p>\n<p><a class=\"btn\" href=\"https:\/\/uplastech.com\/ru\/%d1%81%d0%b2%d1%8f%d0%b7%d0%b0%d1%82%d1%8c%d1%81%d1%8f-%d1%81\/\">Talk to our thick-gauge forming team<\/a><\/p>\n<\/div>\n<div class=\"rel\">\n<h4>Continue reading<\/h4>\n<ul>\n<li><a href=\"https:\/\/uplastech.com\/ru\/thermoforming-cnc-trimming\/\">CNC Trimming of Thermoformed Parts: The Machine Is Not Where Your Error Comes From<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/ru\/thermoforming-trim-fixture\/\">Trim Fixtures for Thermoformed Parts: Where the Accuracy Comes From<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/ru\/thermoforming-trimming-methods\/\">Trimming Thermoformed Parts: Steel Rule, Router and Punch Compared<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/ru\/profile-cnc-fabrication\/\">CNC Fabrication of Extruded Profiles: Machining a Part That Was Never Flat<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/ru\/thermoforming-tolerances\/\">Thermoforming Tolerances: What a Formed Part Can Actually Hold<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>A formed housing can be dimensionally sound yet fail assembly when the CNC trim is referenced to the wrong datum; define the locating scheme up front.<\/p>","protected":false},"author":1,"featured_media":11975,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[29],"tags":[],"class_list":["post-10263","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vacuum-forming"],"meta_box":{"post-to-quiz_to":[]},"_links":{"self":[{"href":"https:\/\/uplastech.com\/ru\/wp-json\/wp\/v2\/posts\/10263","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/uplastech.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/uplastech.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/uplastech.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/uplastech.com\/ru\/wp-json\/wp\/v2\/comments?post=10263"}],"version-history":[{"count":1,"href":"https:\/\/uplastech.com\/ru\/wp-json\/wp\/v2\/posts\/10263\/revisions"}],"predecessor-version":[{"id":11955,"href":"https:\/\/uplastech.com\/ru\/wp-json\/wp\/v2\/posts\/10263\/revisions\/11955"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/uplastech.com\/ru\/wp-json\/wp\/v2\/media\/11975"}],"wp:attachment":[{"href":"https:\/\/uplastech.com\/ru\/wp-json\/wp\/v2\/media?parent=10263"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/uplastech.com\/ru\/wp-json\/wp\/v2\/categories?post=10263"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/uplastech.com\/ru\/wp-json\/wp\/v2\/tags?post=10263"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}