{"id":9710,"date":"2024-02-13T01:00:00","date_gmt":"2024-02-13T01:00:00","guid":{"rendered":"https:\/\/uplastech.com\/injection-first-article-cavity-by-cavity-dimension-report\/"},"modified":"2026-11-08T08:18:24","modified_gmt":"2026-11-08T08:18:24","slug":"injection-first-article-cavity-by-cavity-dimension-report","status":"publish","type":"post","link":"https:\/\/uplastech.com\/pt\/injection-first-article-cavity-by-cavity-dimension-report\/","title":{"rendered":"Cavity-by-Cavity Dimension Reporting at First Article"},"content":{"rendered":"<style>\n.upl-blog{font-size:17px;line-height:1.78;color:#1f2937}\n.upl-blog p{margin:0 0 18px}\n.upl-blog h2{font-size:26px;line-height:1.3;color:#0b2b33;margin:46px 0 14px;font-weight:700;letter-spacing:-.015em}\n.upl-blog h3{font-size:19.5px;color:#0d3b47;margin:28px 0 10px;font-weight:700}\n.upl-blog ul,.upl-blog ol{margin:0 0 20px;padding-left:22px}\n.upl-blog li{margin:0 0 9px}\n.upl-blog figure{margin:0 0 34px}\n.upl-blog figure img{width:100%;height:auto;display:block;border-radius:10px}\n.upl-blog figcaption{font-size:13px;color:#6b7280;margin-top:10px;line-height:1.5}\n.upl-blog .toc{background:none;border:0;border-radius:0;padding:0;margin:0 0 34px}\n.upl-blog .toc .lwptoc{margin:0}\n.upl-blog .toc h4{margin:0 0 10px;font-size:13px;letter-spacing:.1em;text-transform:uppercase;color:#0d5563}\n.upl-blog .toc ol{margin:0;padding-left:18px;font-size:14.5px}\n.upl-blog .toc li{margin-bottom:6px}\n.upl-blog table{width:100%;border-collapse:collapse;font-size:14.5px;margin:0 0 10px}\n.upl-blog th{background:#0d3b47;color:#fff;text-align:left;padding:11px 13px;font-weight:600;font-size:13.5px;border:0}\n.upl-blog td{padding:11px 13px;border:0;border-bottom:1px solid #e8ebed;vertical-align:top}\n.upl-blog tbody tr:nth-child(even){background:#fafbfc}\n.upl-blog .tablecap{font-size:12.5px;color:#6b7280;margin:0 0 30px}\n.upl-blog .myth{background:#fff8ef;border:1px solid #f6ddbd;border-radius:8px;padding:16px 20px;margin:0 0 26px;font-size:15.5px}\n.upl-blog .myth b{color:#a85c10}\n.upl-blog .callout{background:#f2f8f9;border-radius:8px;padding:18px 22px;margin:0 0 26px;font-size:15.5px;border-left:3px solid #14707f}\n.upl-blog .faq h3{border-top:1px solid #eceff1;padding-top:22px;margin-top:0;font-size:18px}\n.upl-blog .faq h3:first-of-type{border-top:0;padding-top:0}\n.upl-blog .cta{background:linear-gradient(135deg,#0b2b33,#0d5563);color:#fff;border-radius:12px;padding:34px;margin:48px 0 30px}\n.upl-blog .cta h2,.upl-blog .cta .cta-h{color:#fff;margin:0 0 10px;font-size:24px;font-weight:700;line-height:1.3}\n.upl-blog .cta p{color:#c9dee3;margin:0 0 20px;font-size:16px}\n.upl-blog .btn{display:inline-block;background:#e07a1f;color:#fff;text-decoration:none;font-weight:700;padding:13px 26px;border-radius:8px;font-size:15.5px}\n.upl-blog .rel{border-top:1px solid #e8ebed;margin-top:40px;padding-top:26px}\n.upl-blog .rel h4{font-size:13px;letter-spacing:.1em;text-transform:uppercase;color:#6b7280;margin:0 0 14px}\n.upl-blog .rel ul{list-style:none;padding:0;margin:0}\n.upl-blog .rel li{padding:11px 0;border-bottom:1px dashed #e8ebed}\n.upl-blog .rel a{text-decoration:none;font-weight:600;font-size:15.5px}\n\/* ==UPL-CONVERSION-MODULES-START== 2024 problem-solving \/ lead-gen blocks *\/\n.upl-blog .mod-h{font-size:12.5px;letter-spacing:.12em;text-transform:uppercase;font-weight:700;color:#0d5563;margin:0 0 12px}\n.upl-blog .problem{background:#fff8f3;border:1px solid #f3ddc9;border-left:4px solid #e07a1f;border-radius:10px;padding:22px 26px;margin:0 0 32px;font-size:16px}\n.upl-blog .problem p{margin:0 0 10px}\n.upl-blog .problem p:last-child{margin-bottom:0}\n.upl-blog .problem .mod-h{color:#a85c10}\n.upl-blog .problem .problem-promise{font-weight:700;color:#0b2b33}\n.upl-blog .steps{background:#f7fafb;border:1px solid #e1ebee;border-radius:10px;padding:22px 26px;margin:0 0 28px}\n.upl-blog .steps ol{list-style:none;counter-reset:uplst;margin:0;padding:0}\n.upl-blog .steps li{counter-increment:uplst;position:relative;padding:0 0 16px 42px;margin:0;font-size:15.5px}\n.upl-blog .steps li:last-child{padding-bottom:0}\n.upl-blog .steps li::before{content:counter(uplst);position:absolute;left:0;top:2px;width:26px;height:26px;border-radius:50%;background:#0d5563;color:#fff;font-size:13px;font-weight:700;line-height:26px;text-align:center}\n.upl-blog table.spec th{background:#14707f}\n.upl-blog .conv{background:#eef6f7;border:1px solid #cfe4e8;border-radius:10px;padding:24px 26px;margin:32px 0}\n.upl-blog .conv p{margin:0 0 12px;font-size:15.5px}\n.upl-blog .conv .conv-lbl{font-weight:700;color:#0b2b33;margin:16px 0 8px}\n.upl-blog ul.conv-need{list-style:none;padding:0;margin:0 0 20px;display:grid;grid-template-columns:1fr 1fr;gap:6px 18px}\n.upl-blog ul.conv-need li{position:relative;padding-left:20px;margin:0;font-size:14.5px}\n.upl-blog ul.conv-need li::before{content:\"\";position:absolute;left:0;top:9px;width:9px;height:9px;border:2px solid #14707f;border-radius:2px}\n.upl-blog .conv-btn{display:inline-block;background:#0d5563;color:#fff;text-decoration:none;font-weight:700;padding:11px 22px;border-radius:7px;font-size:15px}\n.upl-blog .checklist{background:#fbfcfd;border:1px solid #e3e9ec;border-radius:10px;padding:24px 26px;margin:36px 0}\n.upl-blog .checklist ul{list-style:none;padding:0;margin:0 0 12px}\n.upl-blog .checklist li{position:relative;padding-left:28px;margin:0 0 10px;font-size:15.5px}\n.upl-blog .checklist li::before{content:\"\";position:absolute;left:0;top:7px;width:14px;height:14px;border:2px solid #0d5563;border-radius:3px}\n.upl-blog .cl-note{font-size:13.5px;color:#6b7280;margin:0}\n.upl-blog .cta .cta-lbl{color:#c9dee3;font-weight:700;margin:0 0 8px;font-size:14.5px}\n.upl-blog ul.cta-need{list-style:none;padding:0;margin:0 0 22px;display:grid;grid-template-columns:1fr 1fr;gap:4px 18px}\n.upl-blog ul.cta-need li{color:#e4f0f2;font-size:14.5px;padding-left:18px;position:relative;margin:0}\n.upl-blog ul.cta-need li::before{content:\"\\2713\";position:absolute;left:0;color:#e07a1f;font-weight:700}\n\/* ==UPL-CONVERSION-MODULES-END== *\/\n@media(max-width:640px){.upl-blog h2{font-size:22px}.upl-blog table{font-size:13px}.upl-blog .cta{padding:24px}.upl-blog ul.conv-need,.upl-blog ul.cta-need{grid-template-columns:1fr}.upl-blog .problem,.upl-blog .steps,.upl-blog .conv,.upl-blog .checklist{padding:18px}}\n\/* \u5355\u7bc7\u9875\u9690\u85cf WhatsApp \u95ee\u5019\u5361\uff0c\u53ea\u4fdd\u7559\u5706\u5f62\u6c14\u6ce1\uff0c\u907f\u514d\u906e\u6321\u4fa7\u680f\u8be2\u76d8\u63d0\u4ea4\u6309\u94ae\u3002\n   \u6ce8\u610f\uff1aClick to Chat \u7684\u70b9\u51fb\u903b\u8f91\u662f\u300c\u95ee\u5019\u5361\u5143\u7d20\u5b58\u5728\u5c31\u4e0d\u8df3\u8f6c\u300d\uff0c\u53ea\u9760 CSS \u9690\u85cf\u4f1a\u8ba9\u6c14\u6ce1\u53d8\u6210\u6b7b\u94fe\u63a5\u3002\n   Code Snippets #9\u300cUPL single post: WhatsApp bubble jumps straight to chat\u300d\u8d1f\u8d23\u628a\u8be5\u8282\u70b9\u4ece DOM \u79fb\u9664\uff0c\n   \u4e0b\u9762\u8fd9\u6761 CSS \u53ea\u662f\u79fb\u9664\u524d\u7684\u89c6\u89c9\u515c\u5e95\u3002\u5220 #9 \u524d\u5fc5\u987b\u5148\u5220\u8fd9\u6761\u89c4\u5219\u3002 *\/\nbody.single-post .ht_ctc_chat_greetings_box{display:none !important}\n<\/style>\n<div class=\"upl-blog\">\n<figure>\n<img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/uplastech.com\/wp-content\/uploads\/2026\/11\/2024-injection-first-article-cavity-by-cavity-dimension-report-hero.jpg\" alt=\"Real production view of an injection moulding machine and moulded parts\" width=\"1536\" height=\"909\"><figcaption>Real injection molding production context. Photo: Pexels.<\/figcaption><\/figure>\n<div class=\"problem\">\n<p class=\"mod-h\">The problem<\/p>\n<p><b>Symptom.<\/b> A first-article report covers only cavity 1 of an 8-cavity tool, but the customer requires every cavity dimension signed off before series release.<\/p>\n<p><b>What it costs.<\/b> When a downstream cavity drifts, an illustrative 3 shifts of sorting and a 2 % scrap allowance are needed before the real cavity balance is known.<\/p>\n<p class=\"problem-promise\">This article quantifies the coverage gap, sets the full-cavity requirement, and writes the cavity map into the first-article report so no cavity is left unverified.<\/p>\n<\/div>\n<div class=\"toc\"><\/div>\n<h2 id=\"when-the-first-article-covers-only-one-cavity\">When the first article covers only one cavity<\/h2>\n<p>In one illustrative first article an 8-cavity tool is reported from cavity 1 only, so the customer sees 12 of 96 cavity dimensions and signs off blind to the other seven. A later cavity drift is then discovered only after parts reach the line.<\/p>\n<table>\n<thead>\n<tr>\n<th>FAI trigger<\/th>\n<th>What it hides<\/th>\n<th>First figure to check<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Only cavity 1 measured<\/td>\n<td>7 of 8 cavities unseen<\/td>\n<td>Dimensions reported vs 96<\/td>\n<\/tr>\n<tr>\n<td>No cavity map in report<\/td>\n<td>Balance spread unknown<\/td>\n<td>Worst-cavity deviation<\/td>\n<\/tr>\n<tr>\n<td>Downstream drift found<\/td>\n<td>Illustrative 3-shift sort<\/td>\n<td>Scrap allowance 2 %<\/td>\n<\/tr>\n<tr>\n<td>Sign-off rushed<\/td>\n<td>Series released blind<\/td>\n<td>Cavity count of the tool<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"tablecap\">Table 1 - Reading a single-cavity first-article before series release<\/p>\n<div class=\"callout\">Record which of these you are actually seeing before changing any setting. Two faults can look identical on the line and need opposite corrections.<\/div>\n<p><!-- upl-conv-v1 quickcta --><\/p>\n<div class=\"quickcta\">\n<p class=\"mod-h\">Need a fixed price for this moulded part?<\/p>\n<p>Send the 2D drawing, resin grade and annual volume. Our engineers return a DFM review, a material recommendation and a written quotation you can compare line by line.<\/p>\n<p class=\"quickcta-act\"><a class=\"quickcta-btn\" href=\"https:\/\/uplastech.com\/injection-molding\/\">Get a moulding quotation<\/a><a class=\"quickcta-alt\" href=\"mailto:john@uplastech.com\">Email john@uplastech.com<\/a><a class=\"quickcta-alt\" href=\"https:\/\/wa.me\/8617717529949\">WhatsApp<\/a><\/p>\n<\/div>\n<h2 id=\"quantify-the-coverage-gap-across-eight-cavities\">Quantify the coverage gap across eight cavities<\/h2>\n<p>Size the gap before release. Measuring 1, 2, 4, 6 then 8 cavities reports an illustrative 12, 25, 50, 75 and 100 % of dimensions; the single-cavity report therefore hides 88 % of the picture. These are illustrative worked values from stated assumptions, not a measured series or a quoted result.<\/p>\n<div class=\"steps\">\n<p class=\"mod-h\">A five-step diagnostic sequence<\/p>\n<ol>\n<li><b>Measure cavity 1 first.<\/b><br \/>Record the 12 dimensions at cavity 1 to confirm the method before the sweep.<\/li>\n<li><b>Sweep cavities 2 to 8.<\/b><br \/>Repeat the 12 dimensions on every cavity so all 96 points are on the map.<\/li>\n<li><b>Compare the balance.<\/b><br \/>Flag any cavity whose spread exceeds the stated band before sign-off.<\/li>\n<li><b>Reserve the allowance.<\/b><br \/>Hold an illustrative 2 % scrap allowance against the worst cavity in the report.<\/li>\n<li><b>File the cavity map.<\/b><br \/>Attach one row per cavity so the customer sees the full tool, not cavity 1.<\/li>\n<\/ol>\n<\/div>\n<p>The chart below is a typical result from that measurement step. Use it to separate a design limit from a setting that can still be recovered.<\/p>\n<figure>\n<img decoding=\"async\" src=\"https:\/\/uplastech.com\/wp-content\/uploads\/2026\/11\/injection-first-article-cavity-by-cavity-dimension-report-chart.jpg\" alt=\"Cavity-by-Cavity Dimension Reporting at First Article: calculated response trend and an illustrative root-cause split\" width=\"1536\" height=\"909\"><figcaption>Figure 1 \u2014 Calculated response trend and an illustrative root-cause split. Values are engineering guidance for diagnosis, not a measured survey; confirm them on your own line before changing a drawing or a specification.<\/figcaption><\/figure>\n<h2 id=\"set-the-full-cavity-reporting-requirement\">Set the full-cavity reporting requirement<\/h2>\n<p>Set the requirement at full cavity coverage with a balance check. With 8 cavities the report must show all 96 points plus an illustrative 2 % scrap allowance reserved for the worst cavity. These are illustrative worked values from stated assumptions, not a market survey, a quoted price or a measured series.<\/p>\n<table class=\"spec\">\n<thead>\n<tr>\n<th>Clause or parameter<\/th>\n<th>Agreed value<\/th>\n<th>What goes wrong outside it<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Cavity coverage<\/td>\n<td>All 8 cavities mapped<\/td>\n<td>7 cavities released blind<\/td>\n<\/tr>\n<tr>\n<td>Balance check<\/td>\n<td>Worst cavity flagged<\/td>\n<td>Drift found on the line<\/td>\n<\/tr>\n<tr>\n<td>Scrap allowance<\/td>\n<td>2 % worst cavity<\/td>\n<td>Sort cost blows up<\/td>\n<\/tr>\n<tr>\n<td>Re-map on tooling<\/td>\n<td>Every tool change<\/td>\n<td>Balance lost after move<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"tablecap\">Table 2 - Cavity-reporting clauses for the first-article report<\/p>\n<h2 id=\"a-controlled-first-article-measurement-sequence\">A controlled first-article measurement sequence<\/h2>\n<p>Run the measurement in a fixed order: measure cavity 1, confirm the method, sweep cavities 2 to 8, then compare the balance. The table ranks the actions by release risk so the cavity map is never skipped under schedule pressure.<\/p>\n<table>\n<thead>\n<tr>\n<th>Control action<\/th>\n<th>What it fixes<\/th>\n<th>Cost or trade-off<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Map all 8 cavities<\/td>\n<td>Full dimension coverage<\/td>\n<td>Extra measurement time<\/td>\n<\/tr>\n<tr>\n<td>Add balance check<\/td>\n<td>Catches worst cavity<\/td>\n<td>One row per cavity<\/td>\n<\/tr>\n<tr>\n<td>Reserve 2 % allowance<\/td>\n<td>Covers worst cavity<\/td>\n<td>Scrap cost held<\/td>\n<\/tr>\n<tr>\n<td>Re-map after tooling<\/td>\n<td>No drift after change<\/td>\n<td>One owner to maintain<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"tablecap\">Table 3 - Cavity-coverage controls ranked by release risk<\/p>\n<div class=\"myth\"><b>Myth:<\/b> \"A process adjustment will fix it.\" Once a design limit is reached, more tuning only adds cost and variation. Confirm the limit with a measurement, then change the drawing or the specification.<\/div>\n<h2 id=\"write-the-cavity-map-into-the-fai-report\">Write the cavity map into the FAI report<\/h2>\n<p>Put the cavity map in the first-article report: one row per cavity, the 12 dimensions, and the balance spread. A written map turns a single-cavity sign-off into a tool-wide release the customer can trust.<\/p>\n<div class=\"conv\">\n<p class=\"mod-h\">Not sure whether the fault is in the tool or the process?<\/p>\n<p>Send us the drawing, the process window and a few sample parts. We will tell you which change fixes the fault before you commit to a tool modification.<\/p>\n<p class=\"conv-lbl\">What to send us<\/p>\n<ul class=\"conv-need\">\n<li>Part drawing with the affected dimension<\/li>\n<li>Current process settings<\/li>\n<li>Sample parts from a good and a bad batch<\/li>\n<li>Annual volume<\/li>\n<\/ul>\n<p><a class=\"conv-btn\" href=\"\/injection-molding\/\">Send the part for review<\/a>\n<\/div>\n<h2 id=\"keep-the-cavity-balance-current-after-tooling-changes\">Keep the cavity balance current after tooling changes<\/h2>\n<p>Re-measure the balance after any tooling change, record the 2 % allowance actually used, and re-forecast the cavity spread. A written map reviewed on dated evidence settles the coverage question at first article rather than on the line.<\/p>\n<div class=\"callout\">Validate one change at a time and keep the measurement record. A supplier discussion backed by data is resolved in days, not weeks.<\/div>\n<div class=\"checklist\">\n<p class=\"mod-h\">Before you release this injection moulding job<\/p>\n<ul>\n<li>The first-article report maps all 8 cavities, not only cavity 1<\/li>\n<li>The 12 dimensions are recorded on every cavity for full coverage<\/li>\n<li>A balance check flags the worst cavity before series release<\/li>\n<li>A 2 % scrap allowance is reserved against the worst cavity<\/li>\n<li>The cavity map is re-run after any tooling or process change<\/li>\n<\/ul>\n<p class=\"cl-note\">Attach this list to the RFQ. Most moulding faults are decided at the drawing stage.<\/p>\n<\/div>\n<div class=\"faq\">\n<h3>Why report every cavity?<\/h3>\n<p>An 8-cavity tool can drift on one cavity while the rest stay true. A cavity-1 report hides 88 % of the picture, so a downstream cavity fails only after parts reach the line.<\/p>\n<h3>How much does single-cavity hide?<\/h3>\n<p>Using illustrative assumptions, 1 of 8 cavities reports 12 % of dimensions; the remaining 88 % is unseen until a drift is found in production.<\/p>\n<h3>What is the balance check?<\/h3>\n<p>It compares the spread of all 8 cavities and flags the worst one. With 8 cavities an illustrative 2 % scrap allowance is reserved against that cavity.<\/p>\n<h3>Can we sample cavities?<\/h3>\n<p>Only if the customer agrees a reduced plan. The default requirement is full cavity coverage with a balance check at first article.<\/p>\n<h3>Who owns the cavity map?<\/h3>\n<p>A named owner re-runs it after tooling changes. Without one owner the balance is lost the moment the tool is touched.<\/p>\n<h3>Does the map expire?<\/h3>\n<p>It is valid until the tool or process changes. Re-mapping at each change keeps the evidence current without re-measuring every lot.<\/p>\n<\/div>\n<div class=\"cta\">\n<p class=\"cta-h\">Get a mouldable part and a fixed quotation<\/p>\n<p>Send us the part file and the failure history. Our engineers will return a DFM review, a material recommendation and a fixed quotation with a defined first-article acceptance test.<\/p>\n<p class=\"cta-lbl\">To get an accurate quote, send:<\/p>\n<ul class=\"cta-need\">\n<li>3D file or 2D part drawing<\/li>\n<li>Resin grade and any regrind limit<\/li>\n<li>Annual volume and target unit price<\/li>\n<li>The failed sample or defect photos<\/li>\n<\/ul>\n<p><a class=\"btn\" href=\"\/injection-molding\/\">Request a DFM review and quote<\/a><br \/>\n<!-- upl-conv-v1 contact --><\/p>\n<div class=\"contactbar\">\n<p class=\"contactbar-h\">Prefer to talk it through first?<\/p>\n<p>Email <a href=\"mailto:john@uplastech.com\">john@uplastech.com<\/a> or message us on <a href=\"https:\/\/wa.me\/8617717529949\">WhatsApp +86 177 1752 9949<\/a>. Send a drawing, a sample or a specification and an engineer will reply.<\/p>\n<\/div>\n<p><!-- upl-conv-v1 trust --><\/p>\n<div class=\"trust\">\n<p class=\"trust-h\">Why buyers work with Uplastech<\/p>\n<p>ISO 9001, ISO 14001 and ISO 45001 certified. Founded in 2016, with injection moulding lines in Shanghai and an extrusion plant in Jiangsu. Moulding machines from 90T to 1100T and a maximum shot weight of 5100 g. Samples and a written quotation are available on request.<\/p>\n<\/div>\n<\/div>\n<div class=\"rel\">\n<h4>Continue reading<\/h4>\n<ul>\n<li><a href=\"https:\/\/uplastech.com\/injection-molding-tolerances\/\">Injection molding tolerances: what to specify<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/snap-fit-design\/\">Snap-fit design: strain, deflection and retention<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/plastic-part-assembly-design\/\">Plastic part assembly design<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/dfm-review-checklist\/\">DFM review checklist<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/injection-molding-material-selection\/\">Injection molding material selection<\/a><\/li>\n<\/ul>\n<p><!-- upl-conv-v1 service --><\/p>\n<p class=\"rel-svc\">Ready to specify? See our <a href=\"https:\/\/uplastech.com\/injection-molding\/\">injection moulding services<\/a> or <a href=\"mailto:john@uplastech.com\">request a written quotation<\/a>.<\/p>\n<\/div>\n<\/div>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Why report every cavity?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"An 8-cavity tool can drift on one cavity while the rest stay true. A cavity-1 report hides 88 % of the picture, so a downstream cavity fails only after parts reach the line.\"}}, {\"@type\": \"Question\", \"name\": \"How much does single-cavity hide?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Using illustrative assumptions, 1 of 8 cavities reports 12 % of dimensions; the remaining 88 % is unseen until a drift is found in production.\"}}, {\"@type\": \"Question\", \"name\": \"What is the balance check?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It compares the spread of all 8 cavities and flags the worst one. With 8 cavities an illustrative 2 % scrap allowance is reserved against that cavity.\"}}, {\"@type\": \"Question\", \"name\": \"Can we sample cavities?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Only if the customer agrees a reduced plan. The default requirement is full cavity coverage with a balance check at first article.\"}}, {\"@type\": \"Question\", \"name\": \"Who owns the cavity map?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"A named owner re-runs it after tooling changes. Without one owner the balance is lost the moment the tool is touched.\"}}, {\"@type\": \"Question\", \"name\": \"Does the map expire?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It is valid until the tool or process changes. Re-mapping at each change keeps the evidence current without re-measuring every lot.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>This article quantifies the coverage gap, sets the full-cavity requirement, and writes the cavity map into the first-article report so no cavity is left unverified.<\/p>","protected":false},"author":1,"featured_media":9708,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[35],"tags":[],"class_list":["post-9710","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-injection-molding"],"meta_box":{"post-to-quiz_to":[]},"_links":{"self":[{"href":"https:\/\/uplastech.com\/pt\/wp-json\/wp\/v2\/posts\/9710","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/uplastech.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/uplastech.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/uplastech.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/uplastech.com\/pt\/wp-json\/wp\/v2\/comments?post=9710"}],"version-history":[{"count":1,"href":"https:\/\/uplastech.com\/pt\/wp-json\/wp\/v2\/posts\/9710\/revisions"}],"predecessor-version":[{"id":10035,"href":"https:\/\/uplastech.com\/pt\/wp-json\/wp\/v2\/posts\/9710\/revisions\/10035"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/uplastech.com\/pt\/wp-json\/wp\/v2\/media\/9708"}],"wp:attachment":[{"href":"https:\/\/uplastech.com\/pt\/wp-json\/wp\/v2\/media?parent=9710"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/uplastech.com\/pt\/wp-json\/wp\/v2\/categories?post=9710"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/uplastech.com\/pt\/wp-json\/wp\/v2\/tags?post=9710"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}