{"id":8567,"date":"2026-07-04T09:00:00","date_gmt":"2026-07-04T08:00:00","guid":{"rendered":"https:\/\/uplastech.com\/silicone-flame-retardancy\/"},"modified":"2026-11-02T02:27:25","modified_gmt":"2026-11-02T02:27:25","slug":"silicone-flame-retardancy","status":"publish","type":"post","link":"https:\/\/uplastech.com\/it\/silicone-flame-retardancy\/","title":{"rendered":"Flame Retardant Silicone: What It Costs and How It Is Measured"},"content":{"rendered":"<style>\n.upl-blog{font-size:17px;line-height:1.78;color:#1f2937}\n.upl-blog p{margin:0 0 18px}\n.upl-blog h2{font-size:26px;line-height:1.3;color:#0b2b33;margin:46px 0 14px;font-weight:700;letter-spacing:-.015em}\n.upl-blog h3{font-size:19.5px;color:#0d3b47;margin:28px 0 10px;font-weight:700}\n.upl-blog ul,.upl-blog ol{margin:0 0 20px;padding-left:22px}\n.upl-blog li{margin:0 0 9px}\n.upl-blog figure{margin:0 0 34px}\n.upl-blog figure img{width:100%;height:auto;display:block;border-radius:10px}\n.upl-blog figcaption{font-size:13px;color:#6b7280;margin-top:10px;line-height:1.5}\n.upl-blog .toc{background:none;border:0;border-radius:0;padding:0;margin:0 0 34px}\n.upl-blog .toc .lwptoc{margin:0}\n.upl-blog .toc h4{margin:0 0 10px;font-size:13px;letter-spacing:.1em;text-transform:uppercase;color:#0d5563}\n.upl-blog .toc ol{margin:0;padding-left:18px;font-size:14.5px}\n.upl-blog .toc li{margin-bottom:6px}\n.upl-blog table{width:100%;border-collapse:collapse;font-size:14.5px;margin:0 0 10px}\n.upl-blog th{background:#0d3b47;color:#fff;text-align:left;padding:11px 13px;font-weight:600;font-size:13.5px;border:0}\n.upl-blog td{padding:11px 13px;border:0;border-bottom:1px solid #e8ebed;vertical-align:top}\n.upl-blog tbody tr:nth-child(even){background:#fafbfc}\n.upl-blog .tablecap{font-size:12.5px;color:#6b7280;margin:0 0 30px}\n.upl-blog .myth{background:#fff8ef;border:1px solid #f6ddbd;border-radius:8px;padding:16px 20px;margin:0 0 26px;font-size:15.5px}\n.upl-blog .myth b{color:#a85c10}\n.upl-blog .callout{background:#f2f8f9;border-radius:8px;padding:18px 22px;margin:0 0 26px;font-size:15.5px;border-left:3px solid #14707f}\n.upl-blog .faq h3{border-top:1px solid #eceff1;padding-top:22px;margin-top:0;font-size:18px}\n.upl-blog .faq h3:first-of-type{border-top:0;padding-top:0}\n.upl-blog .cta{background:linear-gradient(135deg,#0b2b33,#0d5563);color:#fff;border-radius:12px;padding:34px;margin:48px 0 30px}\n.upl-blog .cta h2,.upl-blog .cta .cta-h{color:#fff;margin:0 0 10px;font-size:24px;font-weight:700;line-height:1.3}\n.upl-blog .cta p{color:#c9dee3;margin:0 0 20px;font-size:16px}\n.upl-blog .btn{display:inline-block;background:#e07a1f;color:#fff;text-decoration:none;font-weight:700;padding:13px 26px;border-radius:8px;font-size:15.5px}\n.upl-blog .rel{border-top:1px solid #e8ebed;margin-top:40px;padding-top:26px}\n.upl-blog .rel h4{font-size:13px;letter-spacing:.1em;text-transform:uppercase;color:#6b7280;margin:0 0 14px}\n.upl-blog .rel ul{list-style:none;padding:0;margin:0}\n.upl-blog .rel li{padding:11px 0;border-bottom:1px dashed #e8ebed}\n.upl-blog .rel a{text-decoration:none;font-weight:600;font-size:15.5px}\n@media(max-width:640px){.upl-blog h2{font-size:22px}.upl-blog table{font-size:13px}.upl-blog .cta{padding:24px}}\n\/* \u5355\u7bc7\u9875\u9690\u85cf WhatsApp \u95ee\u5019\u5361\uff0c\u53ea\u4fdd\u7559\u5706\u5f62\u6c14\u6ce1\uff0c\u907f\u514d\u906e\u6321\u4fa7\u680f\u8be2\u76d8\u63d0\u4ea4\u6309\u94ae\u3002\n   \u6ce8\u610f\uff1aClick to Chat \u7684\u70b9\u51fb\u903b\u8f91\u662f\u300c\u95ee\u5019\u5361\u5143\u7d20\u5b58\u5728\u5c31\u4e0d\u8df3\u8f6c\u300d\uff0c\u53ea\u9760 CSS \u9690\u85cf\u4f1a\u8ba9\u6c14\u6ce1\u53d8\u6210\u6b7b\u94fe\u63a5\u3002\n   Code Snippets #9\u300cUPL single post: WhatsApp bubble jumps straight to chat\u300d\u8d1f\u8d23\u628a\u8be5\u8282\u70b9\u4ece DOM \u79fb\u9664\uff0c\n   \u4e0b\u9762\u8fd9\u6761 CSS \u53ea\u662f\u79fb\u9664\u524d\u7684\u89c6\u89c9\u515c\u5e95\u3002\u5220 #9 \u524d\u5fc5\u987b\u5148\u5220\u8fd9\u6761\u89c4\u5219\u3002 *\/\nbody.single-post .ht_ctc_chat_greetings_box{display:none !important}\n<\/style>\n<div class=\"upl-blog\">\n<figure>\n<img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/uplastech.com\/wp-content\/uploads\/2026\/11\/silicone-flame-retardancy.jpg\" alt=\"A silicone test piece held in a clamp with a gas flame playing on its lower edge in a laboratory fume hood\" width=\"1536\" height=\"909\"><figcaption>The flame test measures how long it keeps burning. It says nothing about the tear strength.<\/figcaption><\/figure>\n<div class=\"toc\"><\/div>\n<h2 id=\"how\">How silicone burns, and how it is stopped<\/h2>\n<p>Silicone burns cleanly once it is alight: the backbone oxidises to silica, carbon dioxide and water, and there is very little smoke. The problem is not smoke, it is that the material will sustain a flame in air once it has been ignited, and in a cable or a sealing application that is unacceptable.<\/p>\n<p>There are three ways to stop it. A halogen system releases a radical scavenger that interrupts the flame chemistry in the gas phase. A ceramic or intumescent system forms a char layer that insulates the material below. A platinum system promotes crosslinking at the surface so that the material chars instead of burning.<\/p>\n<p>Each has a different cost. The halogen system is the most effective per part per hundred and the least acceptable environmentally, which is why it is being replaced in many markets. The ceramic system is a compromise: less effective, no halogen, and it works by forming an ash that holds the shape.<\/p>\n<p>The platinum system is the most elegant and the least effective on its own. It relies on the material charring rather than dripping, which is enough for some tests and not for others. It is usually combined with a ceramic filler.<\/p>\n<h2 id=\"loi\">Limiting oxygen index<\/h2>\n<p>The limiting oxygen index is the minimum concentration of oxygen in a nitrogen-oxygen mixture that will sustain combustion of the material. Air is 21 percent, so a material with an LOI of 26 will not burn in air once the ignition source is removed, and one with an LOI of 32 will not burn in an atmosphere enriched to 32 percent.<\/p>\n<p>The chart on the left plots LOI against additive loading for the three systems. Unfilled silicone has an LOI of about 26, which is why it self extinguishes in air but still burns in a draught. A halogen system reaches 32 at about 15 parts per hundred and 42 at 40. A ceramic system reaches 32 at about 25 parts and 36 at 40.<\/p>\n<p>Most specifications ask for an LOI of 32 or an equivalent flame test result. That is not an arbitrary number: it is the point at which the material has a comfortable margin over air, and it is the level at which most vertical burn tests are passed.<\/p>\n<p>The LOI is a screening test, not a qualification. A material can have an LOI of 34 and still fail a vertical burn test because of how it drips or how the flame is applied. The specification has to reference the actual test, and the LOI is a useful way of comparing compounds before that test is run.<\/p>\n<figure>\n<img decoding=\"async\" src=\"https:\/\/uplastech.com\/wp-content\/uploads\/2026\/11\/silicone-flame-retardancy-chart.jpg\" alt=\"Limiting oxygen index rising with additive loading for halogen, ceramic and platinum systems, with the LOI 32 line marked, and a bar chart of what flame retardance costs\" width=\"1536\" height=\"909\"><figcaption>Left: LOI against additive loading. Right: what the additive costs in properties.<\/figcaption><\/figure>\n<h2 id=\"cost\">What the additive costs<\/h2>\n<p>A flame retardant is a filler, and fillers change the compound. At the loading needed for an LOI of 32, the hardness rises, the tensile and tear strength fall, and the material becomes harder to process. The chart on the right puts hardness increase at 30 percent of the cost, tensile and tear loss at 26, and material cost at 22.<\/p>\n<p>The hardness increase is the one that catches people out. A compound specified at 60 Shore A becomes 68 after the flame retardant is added, and 68 Shore A is a different seal with a different compression set. The base compound has to be formulated softer so that the finished compound lands on the specified hardness.<\/p>\n<p>The strength loss is the second. A tear strength of 30 kN\/m becomes 22, which on a seal that is stretched over an edge is the difference between lasting and not. The specification has to state the strength at the flame retardant loading, not at the base compound.<\/p>\n<p>The material cost is the visible one and it is not the largest. A halogen free flame retardant system can add 40 to 80 percent to the compound cost, which is significant, but the reformulation and requalification effort is usually larger.<\/p>\n<h2 id=\"tests\">The tests that matter<\/h2>\n<p>UL 94 is the most widely quoted: a vertical burn test on a small bar, classified V-2, V-1 or V-0 depending on how long the material burns and whether it drips. V-0 requires the flame to extinguish within 10 seconds and no dripping that ignites cotton.<\/p>\n<p>The glow wire test, IEC 60695-2-11, is used for electrical applications. A heated wire is applied to the material and the time to ignition and the time to extinguishing are measured. It is closer to a real electrical fault than UL 94.<\/p>\n<p>Cable and construction applications use their own tests, and they are usually more severe than UL 94 because they involve a larger sample and a longer flame. A compound that passes UL 94 V-0 will not necessarily pass a cable tray test.<\/p>\n<p>The important point is that all of these are tests of a specimen, not of a product. A thin wall burns differently from a thick one, a part with a metal insert conducts heat away, and a part in a draught behaves differently from one in still air. The specification has to state the specimen and the condition.<\/p>\n<h2 id=\"specify\">Specifying flame retardant silicone<\/h2>\n<p>The specification needs the flame test with its classification, the specimen thickness, the LOI as a screening value, and the mechanical properties at the flame retardant loading. A specification that quotes only the flame test allows a supplier to meet it with a compound that has lost half its tear strength.<\/p>\n<p>The halogen question should be settled explicitly. Halogen free is a market requirement in some sectors and irrelevant in others, and a compound that is halogen free will need a higher loading and will lose more mechanical property. Deciding it at the specification stage is much cheaper than discovering it at the certification stage.<\/p>\n<p>The colour should be specified with the flame retardant in mind. Many flame retardants are themselves coloured, and a white part may be impossible with a ceramic system. A red or grey part is easy, and the colour has to be chosen with the chemistry rather than after it.<\/p>\n<table>\n<thead>\n<tr>\n<th>Requirement<\/th>\n<th>Typical specification<\/th>\n<th>Note<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Flame test<\/td>\n<td>UL 94 V-0 at the part thickness<\/td>\n<td>State the thickness<\/td>\n<\/tr>\n<tr>\n<td>LOI<\/td>\n<td>32 or above<\/td>\n<td>A screening value, not a qualification<\/td>\n<\/tr>\n<tr>\n<td>Hardness<\/td>\n<td>As specified, after the additive<\/td>\n<td>The base must be softer<\/td>\n<\/tr>\n<tr>\n<td>Tear strength<\/td>\n<td>Above 20 kN\/m at the final loading<\/td>\n<td>Usually the property that fails<\/td>\n<\/tr>\n<tr>\n<td>Alogeno<\/td>\n<td>Free or not, decided explicitly<\/td>\n<td>Affects loading and cost<\/td>\n<\/tr>\n<tr>\n<td>Colour<\/td>\n<td>Chosen with the chemistry<\/td>\n<td>Some systems cannot be white<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"tablecap\">Table 1 \u2014 A flame retardant specification that works<\/p>\n<h2 id=\"process\">Processing a flame retardant compound<\/h2>\n<p>A heavily filled compound is harder to process. The viscosity is higher, so the injection pressure and the mould temperature have to be raised, and the flow length in a thin section is shorter. A part designed for unfilled silicone may not fill with the flame retardant version.<\/p>\n<p>The filler also abrades. A flame retardant compound will wear a mould faster than an unfilled one, and the tool steel and the surface treatment have to be chosen for it. On a high volume part, that is a tool life decision rather than a processing one.<\/p>\n<p>Curing is usually unaffected, but the platinum system can be sensitive to some fillers, in the same way it is sensitive to pigments. A new flame retardant should be tested for cure inhibition on the actual compound before the tool is cut.<\/p>\n<table>\n<thead>\n<tr>\n<th>Change<\/th>\n<th>Effect<\/th>\n<th>Compensation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Higher viscosity<\/td>\n<td>Harder to fill thin sections<\/td>\n<td>More pressure, hotter mould<\/td>\n<\/tr>\n<tr>\n<td>Abrasive filler<\/td>\n<td>Faster tool wear<\/td>\n<td>Hardened steel, coating<\/td>\n<\/tr>\n<tr>\n<td>Cure inhibition risk<\/td>\n<td>Tacky surface<\/td>\n<td>Test the filler for compatibility<\/td>\n<\/tr>\n<tr>\n<td>Higher hardness<\/td>\n<td>Different seal behaviour<\/td>\n<td>Reformulate the base<\/td>\n<\/tr>\n<tr>\n<td>Higher cost<\/td>\n<td>Piece price<\/td>\n<td>Nothing, it is the price of compliance<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"tablecap\">Table 2 \u2014 What changes when the compound becomes flame retardant<\/p>\n<div class=\"faq\">\n<h3>What LOI does flame retardant silicone need?<\/h3>\n<p>About 32 for most specifications, which gives a comfortable margin over the 21 percent of air and is the level at which most vertical burn tests pass. Unfilled silicone is around 26.<\/p>\n<h3>Does flame retardant silicone lose strength?<\/h3>\n<p>Yes. At the loading needed for an LOI of 32, tear strength typically falls by 20 to 30 percent and hardness rises by 6 to 8 Shore A. The specification has to quote the mechanical properties at the final loading.<\/p>\n<h3>What is the difference between halogen and halogen free?<\/h3>\n<p>A halogen system interrupts the flame chemistry in the gas phase and is more effective per part per hundred. A halogen free system forms a char and needs a higher loading, so it loses more mechanical property.<\/p>\n<h3>Can flame retardant silicone be white?<\/h3>\n<p>Often not. Many flame retardants are coloured or darken on curing, so an opaque white may be impossible with a ceramic system. The colour has to be chosen with the chemistry.<\/p>\n<h3>Is UL 94 V-0 enough?<\/h3>\n<p>It depends on the application. UL 94 is a small scale vertical burn test, and cable and construction applications use larger, more severe tests. A compound that passes V-0 will not necessarily pass a cable tray test.<\/p>\n<h3>Does the flame retardant affect processing?<\/h3>\n<p>Yes. The compound is more viscous and more abrasive, so it needs higher pressure, a hotter mould and harder tool steel. It may also inhibit platinum cure, which has to be tested before the tool is cut.<\/p>\n<\/div>\n<div class=\"cta\">\n<p class=\"cta-h\">Need a flame retardant silicone part?<\/p>\n<p>Send the flame test, the part thickness and the mechanical requirements. We will tell you which system can meet both, and what it costs in properties.<\/p>\n<p><a class=\"btn\" href=\"https:\/\/uplastech.com\/it\/custom-injection-molding\/\">Ask about flame retardant silicone<\/a>\n<\/div>\n<div class=\"rel\">\n<h4>Continue reading<\/h4>\n<ul>\n<li><a href=\"https:\/\/uplastech.com\/it\/high-temperature-silicone\/\">High Temperature Silicone: Choosing a Grade That Lasts<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/it\/silicone-compound-formulation\/\">Silicone Compound Formulation: What Goes Into the Mix<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/it\/silicone-rubber-types-guide\/\">Silicone Rubber Types: A Guide to the Families<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/it\/silicone-vs-tpe-vs-natural-rubber\/\">Silicone Against TPE and Natural Rubber: Choosing a Material<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/it\/silicone-mold-design\/\">Silicone Mould Design: Gates, Vents and Parting Lines<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>A flame retardant silicone passes the test because of what was added to it, and the same additive takes 26 percent off the tear strength. The specification has to ask for both, or the part passes the fire test and fails in service.<\/p>","protected":false},"author":1,"featured_media":8565,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[39],"tags":[],"class_list":["post-8567","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-silicone-rubber-products"],"meta_box":{"post-to-quiz_to":[]},"_links":{"self":[{"href":"https:\/\/uplastech.com\/it\/wp-json\/wp\/v2\/posts\/8567","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/uplastech.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/uplastech.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/uplastech.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/uplastech.com\/it\/wp-json\/wp\/v2\/comments?post=8567"}],"version-history":[{"count":1,"href":"https:\/\/uplastech.com\/it\/wp-json\/wp\/v2\/posts\/8567\/revisions"}],"predecessor-version":[{"id":8857,"href":"https:\/\/uplastech.com\/it\/wp-json\/wp\/v2\/posts\/8567\/revisions\/8857"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/uplastech.com\/it\/wp-json\/wp\/v2\/media\/8565"}],"wp:attachment":[{"href":"https:\/\/uplastech.com\/it\/wp-json\/wp\/v2\/media?parent=8567"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/uplastech.com\/it\/wp-json\/wp\/v2\/categories?post=8567"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/uplastech.com\/it\/wp-json\/wp\/v2\/tags?post=8567"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}