{"id":9519,"date":"2024-01-27T01:00:00","date_gmt":"2024-01-27T01:00:00","guid":{"rendered":"https:\/\/uplastech.com\/post-cure-volatile-residue-silicone-parts\/"},"modified":"2026-11-08T08:14:43","modified_gmt":"2026-11-08T08:14:43","slug":"post-cure-volatile-residue-silicone-parts","status":"publish","type":"post","link":"https:\/\/uplastech.com\/ar\/post-cure-volatile-residue-silicone-parts\/","title":{"rendered":"Post-Cure Residues: Record the 200 C for 4 h Cycle"},"content":{"rendered":"<style>\n.upl-blog{font-size:17px;line-height:1.78;color:#1f2937}\n.upl-blog p{margin:0 0 18px}\n.upl-blog h2{font-size:26px;line-height:1.3;color:#0b2b33;margin:46px 0 14px;font-weight:700;letter-spacing:-.015em}\n.upl-blog h3{font-size:19.5px;color:#0d3b47;margin:28px 0 10px;font-weight:700}\n.upl-blog ul,.upl-blog ol{margin:0 0 20px;padding-left:22px}\n.upl-blog li{margin:0 0 9px}\n.upl-blog figure{margin:0 0 34px}\n.upl-blog figure img{width:100%;height:auto;display:block;border-radius:10px}\n.upl-blog figcaption{font-size:13px;color:#6b7280;margin-top:10px;line-height:1.5}\n.upl-blog .toc{background:none;border:0;border-radius:0;padding:0;margin:0 0 34px}\n.upl-blog .toc .lwptoc{margin:0}\n.upl-blog .toc h4{margin:0 0 10px;font-size:13px;letter-spacing:.1em;text-transform:uppercase;color:#0d5563}\n.upl-blog .toc ol{margin:0;padding-left:18px;font-size:14.5px}\n.upl-blog .toc li{margin-bottom:6px}\n.upl-blog table{width:100%;border-collapse:collapse;font-size:14.5px;margin:0 0 10px}\n.upl-blog th{background:#0d3b47;color:#fff;text-align:left;padding:11px 13px;font-weight:600;font-size:13.5px;border:0}\n.upl-blog td{padding:11px 13px;border:0;border-bottom:1px solid #e8ebed;vertical-align:top}\n.upl-blog tbody tr:nth-child(even){background:#fafbfc}\n.upl-blog .tablecap{font-size:12.5px;color:#6b7280;margin:0 0 30px}\n.upl-blog .myth{background:#fff8ef;border:1px solid #f6ddbd;border-radius:8px;padding:16px 20px;margin:0 0 26px;font-size:15.5px}\n.upl-blog .myth b{color:#a85c10}\n.upl-blog .callout{background:#f2f8f9;border-radius:8px;padding:18px 22px;margin:0 0 26px;font-size:15.5px;border-left:3px solid #14707f}\n.upl-blog .faq h3{border-top:1px solid #eceff1;padding-top:22px;margin-top:0;font-size:18px}\n.upl-blog .faq h3:first-of-type{border-top:0;padding-top:0}\n.upl-blog .cta{background:linear-gradient(135deg,#0b2b33,#0d5563);color:#fff;border-radius:12px;padding:34px;margin:48px 0 30px}\n.upl-blog .cta h2,.upl-blog .cta .cta-h{color:#fff;margin:0 0 10px;font-size:24px;font-weight:700;line-height:1.3}\n.upl-blog .cta p{color:#c9dee3;margin:0 0 20px;font-size:16px}\n.upl-blog .btn{display:inline-block;background:#e07a1f;color:#fff;text-decoration:none;font-weight:700;padding:13px 26px;border-radius:8px;font-size:15.5px}\n.upl-blog .rel{border-top:1px solid #e8ebed;margin-top:40px;padding-top:26px}\n.upl-blog .rel h4{font-size:13px;letter-spacing:.1em;text-transform:uppercase;color:#6b7280;margin:0 0 14px}\n.upl-blog .rel ul{list-style:none;padding:0;margin:0}\n.upl-blog .rel li{padding:11px 0;border-bottom:1px dashed #e8ebed}\n.upl-blog .rel a{text-decoration:none;font-weight:600;font-size:15.5px}\n\/* ==UPL-CONVERSION-MODULES-START== 2024 problem-solving \/ lead-gen blocks *\/\n.upl-blog .mod-h{font-size:12.5px;letter-spacing:.12em;text-transform:uppercase;font-weight:700;color:#0d5563;margin:0 0 12px}\n.upl-blog .problem{background:#fff8f3;border:1px solid #f3ddc9;border-left:4px solid #e07a1f;border-radius:10px;padding:22px 26px;margin:0 0 32px;font-size:16px}\n.upl-blog .problem p{margin:0 0 10px}\n.upl-blog .problem p:last-child{margin-bottom:0}\n.upl-blog .problem .mod-h{color:#a85c10}\n.upl-blog .problem .problem-promise{font-weight:700;color:#0b2b33}\n.upl-blog .steps{background:#f7fafb;border:1px solid #e1ebee;border-radius:10px;padding:22px 26px;margin:0 0 28px}\n.upl-blog .steps ol{list-style:none;counter-reset:uplst;margin:0;padding:0}\n.upl-blog .steps li{counter-increment:uplst;position:relative;padding:0 0 16px 42px;margin:0;font-size:15.5px}\n.upl-blog .steps li:last-child{padding-bottom:0}\n.upl-blog .steps li::before{content:counter(uplst);position:absolute;left:0;top:2px;width:26px;height:26px;border-radius:50%;background:#0d5563;color:#fff;font-size:13px;font-weight:700;line-height:26px;text-align:center}\n.upl-blog table.spec th{background:#14707f}\n.upl-blog .conv{background:#eef6f7;border:1px solid #cfe4e8;border-radius:10px;padding:24px 26px;margin:32px 0}\n.upl-blog .conv p{margin:0 0 12px;font-size:15.5px}\n.upl-blog .conv .conv-lbl{font-weight:700;color:#0b2b33;margin:16px 0 8px}\n.upl-blog ul.conv-need{list-style:none;padding:0;margin:0 0 20px;display:grid;grid-template-columns:1fr 1fr;gap:6px 18px}\n.upl-blog ul.conv-need li{position:relative;padding-left:20px;margin:0;font-size:14.5px}\n.upl-blog ul.conv-need li::before{content:\"\";position:absolute;left:0;top:9px;width:9px;height:9px;border:2px solid #14707f;border-radius:2px}\n.upl-blog .conv-btn{display:inline-block;background:#0d5563;color:#fff;text-decoration:none;font-weight:700;padding:11px 22px;border-radius:7px;font-size:15px}\n.upl-blog .checklist{background:#fbfcfd;border:1px solid #e3e9ec;border-radius:10px;padding:24px 26px;margin:36px 0}\n.upl-blog .checklist ul{list-style:none;padding:0;margin:0 0 12px}\n.upl-blog .checklist li{position:relative;padding-left:28px;margin:0 0 10px;font-size:15.5px}\n.upl-blog .checklist li::before{content:\"\";position:absolute;left:0;top:7px;width:14px;height:14px;border:2px solid #0d5563;border-radius:3px}\n.upl-blog .cl-note{font-size:13.5px;color:#6b7280;margin:0}\n.upl-blog .cta .cta-lbl{color:#c9dee3;font-weight:700;margin:0 0 8px;font-size:14.5px}\n.upl-blog ul.cta-need{list-style:none;padding:0;margin:0 0 22px;display:grid;grid-template-columns:1fr 1fr;gap:4px 18px}\n.upl-blog ul.cta-need li{color:#e4f0f2;font-size:14.5px;padding-left:18px;position:relative;margin:0}\n.upl-blog ul.cta-need li::before{content:\"\\2713\";position:absolute;left:0;color:#e07a1f;font-weight:700}\n\/* ==UPL-CONVERSION-MODULES-END== *\/\n@media(max-width:640px){.upl-blog h2{font-size:22px}.upl-blog table{font-size:13px}.upl-blog .cta{padding:24px}.upl-blog ul.conv-need,.upl-blog ul.cta-need{grid-template-columns:1fr}.upl-blog .problem,.upl-blog .steps,.upl-blog .conv,.upl-blog .checklist{padding:18px}}\n\/* \u5355\u7bc7\u9875\u9690\u85cf WhatsApp \u95ee\u5019\u5361\uff0c\u53ea\u4fdd\u7559\u5706\u5f62\u6c14\u6ce1\uff0c\u907f\u514d\u906e\u6321\u4fa7\u680f\u8be2\u76d8\u63d0\u4ea4\u6309\u94ae\u3002\n   \u6ce8\u610f\uff1aClick to Chat \u7684\u70b9\u51fb\u903b\u8f91\u662f\u300c\u95ee\u5019\u5361\u5143\u7d20\u5b58\u5728\u5c31\u4e0d\u8df3\u8f6c\u300d\uff0c\u53ea\u9760 CSS \u9690\u85cf\u4f1a\u8ba9\u6c14\u6ce1\u53d8\u6210\u6b7b\u94fe\u63a5\u3002\n   Code Snippets #9\u300cUPL single post: WhatsApp bubble jumps straight to chat\u300d\u8d1f\u8d23\u628a\u8be5\u8282\u70b9\u4ece DOM \u79fb\u9664\uff0c\n   \u4e0b\u9762\u8fd9\u6761 CSS \u53ea\u662f\u79fb\u9664\u524d\u7684\u89c6\u89c9\u515c\u5e95\u3002\u5220 #9 \u524d\u5fc5\u987b\u5148\u5220\u8fd9\u6761\u89c4\u5219\u3002 *\/\nbody.single-post .ht_ctc_chat_greetings_box{display:none !important}\n<\/style>\n<div class=\"upl-blog\">\n<figure>\n<img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/uplastech.com\/wp-content\/uploads\/2026\/10\/sbr-rubber-parts.jpg\" alt=\"Real moulded silicone seals and O-rings made by Uplastech\" width=\"1536\" height=\"909\"><figcaption>Real silicone rubber production context. Uplastech product photo.<\/figcaption><\/figure>\n<div class=\"problem\">\n<p class=\"mod-h\">The problem<\/p>\n<p><b>Symptom.<\/b> A buyer rejects 4,200 silicone stoppers after headspace GC reads 1,400 ppm total volatiles against a 500 ppm clause, and the oven chart shows the 200 C for 4 h post-cure was skipped.<\/p>\n<p><b>What it costs.<\/b> With no post-cure condition or volatile limit in the specification, a batch with odour and fogging complaints is quarantined and the re-work lands on the moulder.<\/p>\n<p class=\"problem-promise\">This article links peroxide decomposition by-products to a missing post-cure, gives the 200 C for 4 h condition to be confirmed per formulation, TGA and headspace GC verification, and the clause that binds the oven record.<\/p>\n<\/div>\n<div class=\"toc\"><\/div>\n<h2 id=\"when-an-odour-complaint-meets-a-skipped-post-cure\">When an odour complaint meets a skipped post-cure<\/h2>\n<p>A buyer rejects 4,200 silicone stoppers after headspace GC reads 1,400 ppm total volatiles against a 500 ppm clause, and the oven chart shows the 200 C for 4 h post-cure was skipped. The parts are dimensionally correct; the residues are not.<\/p>\n<table>\n<thead>\n<tr>\n<th>What the buyer sees<\/th>\n<th>Document behind it<\/th>\n<th>First clause to check<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Headspace GC reads 1,400 ppm<\/td>\n<td>Post-cure omitted<\/td>\n<td>500 ppm total-volatiles clause<\/td>\n<\/tr>\n<tr>\n<td>Only 'post-cured' on the note<\/td>\n<td>No oven chart<\/td>\n<td>Dated 200 C for 4 h record<\/td>\n<\/tr>\n<tr>\n<td>TGA shows high mass loss<\/td>\n<td>Volatile residues remain<\/td>\n<td>TGA plus headspace GC-MS<\/td>\n<\/tr>\n<tr>\n<td>Compound changed after the trial<\/td>\n<td>Condition no longer valid<\/td>\n<td>Re-confirm 200 C for 4 h per grade<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"tablecap\">Table 1 - Reading a post-cure volatiles gap before booking the lot<\/p>\n<div class=\"callout\">Record which of these you are actually seeing before changing any setting. Two faults can look identical on the line and need opposite corrections.<\/div>\n<p><!-- upl-conv-v1 quickcta --><\/p>\n<div class=\"quickcta\">\n<p class=\"mod-h\">Need a fixed price for this seal?<\/p>\n<p>Send the gland drawing, temperature range, media and annual volume. We will recommend a compound with test data and return samples with a written production quotation.<\/p>\n<p class=\"quickcta-act\"><a class=\"quickcta-btn\" href=\"https:\/\/uplastech.com\/silicone-rubber\/\">Get a silicone seal quotation<\/a><a class=\"quickcta-alt\" href=\"mailto:john@uplastech.com\">Email john@uplastech.com<\/a><a class=\"quickcta-alt\" href=\"https:\/\/wa.me\/8617717529949\">WhatsApp<\/a><\/p>\n<\/div>\n<h2 id=\"ask-for-the-oven-chart-and-a-volatiles-report\">Ask for the oven chart and a volatiles report<\/h2>\n<p>Request the post-cure oven chart with time and temperature plus a TGA or headspace GC volatiles report for the lot. Treat the root-cause split as illustrative engineering guidance to confirm on your own line; a 'post-cured' note has no oven record.<\/p>\n<div class=\"steps\">\n<p class=\"mod-h\">A five-step diagnostic sequence<\/p>\n<ol>\n<li><b>Pull the oven chart.<\/b><br \/>Confirm the post-cure reached 200 C for 4 h and that the chart belongs to the shipped lot.<\/li>\n<li><b>Measure total volatiles.<\/b><br \/>Run headspace GC on the lot and compare the 1,400 ppm figure with the 500 ppm clause.<\/li>\n<li><b>Check by TGA as well.<\/b><br \/>Thermogravimetric mass loss shows whether volatile residues remain after cure.<\/li>\n<li><b>Compare with an uncured control.<\/b><br \/>A drop after post-cure confirms the cycle, rather than the compound, is at fault.<\/li>\n<li><b>Bind the condition in the order.<\/b><br \/>Name 200 C for 4 h, the 500 ppm limit and a dated oven chart per lot.<\/li>\n<\/ol>\n<\/div>\n<p>The chart below is a typical result from that measurement step. Use it to separate a design limit from a setting that can still be recovered.<\/p>\n<figure>\n<img decoding=\"async\" src=\"https:\/\/uplastech.com\/wp-content\/uploads\/2026\/11\/post-cure-volatile-residue-silicone-parts-chart.jpg\" alt=\"Post-Cure Residues: Record the 200 C for 4 h Cycle: calculated response trend and an illustrative root-cause split\" width=\"1536\" height=\"909\"><figcaption>Figure 1 \u2014 Calculated response trend and an illustrative root-cause split. Values are engineering guidance for diagnosis, not a measured survey; confirm them on your own line before changing a drawing or a specification.<\/figcaption><\/figure>\n<h2 id=\"peroxide-by-products-and-the-200-c-for-4-h-condition\">Peroxide by-products and the 200 C for 4 h condition<\/h2>\n<p>Peroxide vulcanisation leaves aromatic ketone and acid by-products that a post-cure drives off at elevated temperature. A typical condition is 200 C for 4 h, but the time and temperature must be confirmed for each compound and section thickness.<\/p>\n<table class=\"spec\">\n<thead>\n<tr>\n<th>Clause or parameter<\/th>\n<th>Required value<\/th>\n<th>What goes wrong outside it<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Cure system<\/td>\n<td>Peroxide, named on the order<\/td>\n<td>Platinum grade quoted against a peroxide condition<\/td>\n<\/tr>\n<tr>\n<td>Post-cure condition<\/td>\n<td>200 C for 4 h, confirmed per compound<\/td>\n<td>A skipped cycle leaves 1,400 ppm volatiles<\/td>\n<\/tr>\n<tr>\n<td>Total volatiles<\/td>\n<td>Below 500 ppm by headspace GC<\/td>\n<td>Odour and fogging complaints<\/td>\n<\/tr>\n<tr>\n<td>Verification<\/td>\n<td>TGA and headspace GC-MS per lot<\/td>\n<td>No comparable figure between lots<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"tablecap\">Table 2 - Post-cure clauses for the part specification and purchase order<\/p>\n<h2 id=\"tga-and-headspace-gc-verification\">TGA and headspace GC verification<\/h2>\n<p>Verify by thermogravimetric analysis for total mass loss and headspace GC-MS for individual species, against an uncured control. The 500 ppm clause is an agreed acceptance figure, so state the method, sampling and units that produced it.<\/p>\n<table>\n<thead>\n<tr>\n<th>Action<\/th>\n<th>What it fixes<\/th>\n<th>Cost or trade-off<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Obtain the oven chart for the lot<\/td>\n<td>Closes the record gap<\/td>\n<td>Low: a records check<\/td>\n<\/tr>\n<tr>\n<td>Re-run headspace GC on retained parts<\/td>\n<td>Confirms the 1,400 ppm figure<\/td>\n<td>Low to medium: laboratory test<\/td>\n<\/tr>\n<tr>\n<td>Apply the post-cure and re-test<\/td>\n<td>Removes the residues<\/td>\n<td>Medium: oven cycle and re-test<\/td>\n<\/tr>\n<tr>\n<td>Re-qualify a low-volatile grade<\/td>\n<td>Clears a persistent exceedance<\/td>\n<td>High: new compound and re-run<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"tablecap\">Table 3 - Recovery actions ranked by cost<\/p>\n<div class=\"myth\"><b>Myth:<\/b> \"A process adjustment will fix it.\" Once a design limit is reached, more tuning only adds cost and variation. Confirm the limit with a measurement, then change the drawing or the specification.<\/div>\n<h2 id=\"write-the-post-cure-and-volatile-limit-into-the-order\">Write the post-cure and volatile limit into the order<\/h2>\n<p>On the order name the peroxide cure system, a post-cure of 200 C for 4 h as the starting condition, and a 500 ppm total-volatiles limit by headspace GC. Require a dated oven chart and volatiles report per lot.<\/p>\n<div class=\"conv\">\n<p class=\"mod-h\">Want a compound check before you re-order?<\/p>\n<p>Send us the gland drawing and the service conditions. We will compare the compound data against your temperature range and return a recommendation with sample parts.<\/p>\n<p class=\"conv-lbl\">What to send us<\/p>\n<ul class=\"conv-need\">\n<li>Gland dimensions and cross-section<\/li>\n<li>Temperature range and media<\/li>\n<li>A failed seal if available<\/li>\n<li>Annual volume<\/li>\n<\/ul>\n<p><a class=\"conv-btn\" href=\"\/silicone-rubber\/\">Send the gland drawing<\/a>\n<\/div>\n<h2 id=\"recovery-actions-ranked-by-cost\">Recovery actions ranked by cost<\/h2>\n<p>For a held lot, first apply the specified post-cure and re-run headspace GC; re-working an existing batch is the cheapest fix. If volatiles still exceed 500 ppm, move to a platinum-cured low-volatile grade and re-qualify, the costliest route.<\/p>\n<div class=\"callout\">Validate one change at a time and keep the measurement record. A supplier discussion backed by data is resolved in days, not weeks.<\/div>\n<div class=\"checklist\">\n<p class=\"mod-h\">Before you release this silicone seal<\/p>\n<ul>\n<li>The purchase order names the cure system and a post-cure of 200 C for 4 h, confirmed for the specific compound<\/li>\n<li>A total-volatiles limit of 500 ppm by headspace GC is stated with method, sampling and units<\/li>\n<li>A dated oven chart with time and temperature is required per production lot<\/li>\n<li>TGA and headspace GC-MS verification is agreed as the evidence method<\/li>\n<li>Any compound or section-thickness change triggers a re-confirmation of the post-cure condition<\/li>\n<\/ul>\n<p class=\"cl-note\">Most cold or heat failures are specification gaps, not bad batches. Fix the specification before changing suppliers.<\/p>\n<\/div>\n<div class=\"faq\">\n<h3>Why were the stoppers rejected?<\/h3>\n<p>Headspace GC read 1,400 ppm total volatiles against a 500 ppm clause, and the oven chart showed the 200 C for 4 h post-cure was skipped.<\/p>\n<h3>What does post-cure remove?<\/h3>\n<p>Peroxide decomposition by-products, mainly aromatic ketones and acids, that cause odour, fogging and elevated extractables if left in the rubber.<\/p>\n<h3>Is 200 C for 4 h universal?<\/h3>\n<p>No. It is a typical starting condition that must be confirmed for each compound and section thickness, then written into the order.<\/p>\n<h3>Which tests verify it?<\/h3>\n<p>Thermogravimetric analysis for total mass loss and headspace GC-MS for the individual volatile species, against an uncured control.<\/p>\n<h3>Can a platinum-cured grade skip post-cure?<\/h3>\n<p>It has no peroxide by-products, but a low-volatile grade may still be post-cured. Confirm the condition for the chosen compound.<\/p>\n<h3>Who owns a skipped cycle?<\/h3>\n<p>Put it in the order: name 200 C for 4 h, a 500 ppm limit and a dated oven chart per lot, settled by records.<\/p>\n<\/div>\n<div class=\"cta\">\n<p class=\"cta-h\">Get a seal specified for the real service conditions<\/p>\n<p>Send us the gland drawing and the service conditions. We will recommend a compound with documented test data, review the squeeze, and supply samples with a production quotation.<\/p>\n<p class=\"cta-lbl\">To get an accurate quote, send:<\/p>\n<ul class=\"cta-need\">\n<li>Gland drawing or seal cross-section<\/li>\n<li>Temperature range and media<\/li>\n<li>Pressure and movement<\/li>\n<li>Annual volume and target unit price<\/li>\n<\/ul>\n<p><a class=\"btn\" href=\"\/silicone-rubber\/\">Request samples and a quotation<\/a><br \/>\n<!-- upl-conv-v1 contact --><\/p>\n<div class=\"contactbar\">\n<p class=\"contactbar-h\">Prefer to talk it through first?<\/p>\n<p>Email <a href=\"mailto:john@uplastech.com\">john@uplastech.com<\/a> or message us on <a href=\"https:\/\/wa.me\/8617717529949\">WhatsApp +86 177 1752 9949<\/a>. Send a drawing, a sample or a specification and an engineer will reply.<\/p>\n<\/div>\n<p><!-- upl-conv-v1 trust --><\/p>\n<div class=\"trust\">\n<p class=\"trust-h\">Why buyers work with Uplastech<\/p>\n<p>ISO 9001, ISO 14001 and ISO 45001 certified. Founded in 2016, with injection moulding lines in Shanghai and an extrusion plant in Jiangsu. Moulding machines from 90T to 1100T and a maximum shot weight of 5100 g. Samples and a written quotation are available on request.<\/p>\n<\/div>\n<\/div>\n<div class=\"rel\">\n<h4>Continue reading<\/h4>\n<ul>\n<li><a href=\"https:\/\/uplastech.com\/silicone-compression-set\/\">Silicone compression set<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/silicone-gasket-seal\/\">Silicone gasket and seal design<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/silicone-hardness-shore-a\/\">Silicone hardness: Shore A<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/silicone-industrial-seals\/\">Silicone industrial seals<\/a><\/li>\n<li><a href=\"https:\/\/uplastech.com\/silicone-o-ring-manufacturing\/\">Silicone o-ring manufacturing<\/a><\/li>\n<\/ul>\n<p><!-- upl-conv-v1 service --><\/p>\n<p class=\"rel-svc\">Ready to specify? See our <a href=\"https:\/\/uplastech.com\/silicone-rubber\/\">silicone rubber moulding services<\/a> or <a href=\"mailto:john@uplastech.com\">request a written quotation<\/a>.<\/p>\n<\/div>\n<\/div>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Why were the stoppers rejected?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Headspace GC read 1,400 ppm total volatiles against a 500 ppm clause, and the oven chart showed the 200 C for 4 h post-cure was skipped.\"}}, {\"@type\": \"Question\", \"name\": \"What does post-cure remove?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Peroxide decomposition by-products, mainly aromatic ketones and acids, that cause odour, fogging and elevated extractables if left in the rubber.\"}}, {\"@type\": \"Question\", \"name\": \"Is 200 C for 4 h universal?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. It is a typical starting condition that must be confirmed for each compound and section thickness, then written into the order.\"}}, {\"@type\": \"Question\", \"name\": \"Which tests verify it?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Thermogravimetric analysis for total mass loss and headspace GC-MS for the individual volatile species, against an uncured control.\"}}, {\"@type\": \"Question\", \"name\": \"Can a platinum-cured grade skip post-cure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It has no peroxide by-products, but a low-volatile grade may still be post-cured. Confirm the condition for the chosen compound.\"}}, {\"@type\": \"Question\", \"name\": \"Who owns a skipped cycle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Put it in the order: name 200 C for 4 h, a 500 ppm limit and a dated oven chart per lot, settled by records.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>This article links peroxide decomposition by-products to a missing post-cure, gives the 200 C for 4 h condition to be confirmed per formulation, TGA and headspace GC verification, and the clause that binds the oven record.<\/p>","protected":false},"author":1,"featured_media":7403,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[39],"tags":[],"class_list":["post-9519","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-silicone-rubber-products"],"meta_box":{"post-to-quiz_to":[]},"_links":{"self":[{"href":"https:\/\/uplastech.com\/ar\/wp-json\/wp\/v2\/posts\/9519","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/uplastech.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/uplastech.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/uplastech.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/uplastech.com\/ar\/wp-json\/wp\/v2\/comments?post=9519"}],"version-history":[{"count":1,"href":"https:\/\/uplastech.com\/ar\/wp-json\/wp\/v2\/posts\/9519\/revisions"}],"predecessor-version":[{"id":9969,"href":"https:\/\/uplastech.com\/ar\/wp-json\/wp\/v2\/posts\/9519\/revisions\/9969"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/uplastech.com\/ar\/wp-json\/wp\/v2\/media\/7403"}],"wp:attachment":[{"href":"https:\/\/uplastech.com\/ar\/wp-json\/wp\/v2\/media?parent=9519"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/uplastech.com\/ar\/wp-json\/wp\/v2\/categories?post=9519"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/uplastech.com\/ar\/wp-json\/wp\/v2\/tags?post=9519"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}